Henny Penny OFG-390 manual Shortening level also referred to as fill lines

Page 49

 

Model OFG- 390

gas control valve

an automatic dual controller that controls gas to both pilot lights and gas

(gas fryers only)

pressure to burners on fryers; if either pilot light goes out, the controller shuts

 

off the gas to the other pilot light

gas valve knob

the knob that opens and closes the gas control valve

(gas fryers only)

 

gas pressure regulator

a device located on the gas control valve that regulates the gas

(gas fryers only)

pressure; the

pressure specifications are preset at the factory

heat indicator

the light that illuminates when the shortening is being heated; the light goes off

 

when the preset shortening temperature has been achieved

heating elements

the coils located inside the frypot on electric fryers that heat the shortening

high limit

a temperature control that opens and shuts off the heat to the frypot if it senses

 

shortening temperature in excess of 420°F (212°C)

ignition modules

two modules that send electrical energy to the spark igniters that ignite the pilot

 

lights on gas fryers

L-shaped brush

a brush included with the fryer that is used to clean around the burner tubes

 

and heating elements

landing table

another name for a dumping table (see dumping table)

level indicator lines

the lines marked on the interior real wall of the frypot that show the proper

 

shortening level (also referred to as fill lines)

lid assembly

an assembly comprised of lid, lid handle, and lid latch which raises and lowers

 

product into shortening on eight head fryers

lid handle

a handle that is attached to the lid and is used to lower the lid into contact with

 

the frypot; the handle is then pulled forward and pushed down to lock the lid in

 

place (see lid latch)

lid latch

a mechanical catch on the front of the fryer lid that engages a bracket located on

 

the front of the frypot; the latch holds the lid down

manual reset lever

resets high limit (OE-100 only)

manual shutoff valve

a valve located between the fryer and the wall that shuts off the flow of gas from

(gas fryers only)

the supply line; this is not the main shutoff valve for the store

melt cycle

a heat mode that cycles on and off to slowly melt the shortening when the

 

power switch is on and the shortening temperature is below a certain

 

temperature; the melt cycle prevents scorching of the shortening

pilot orifice

a controlled opening for the pilot light located on the burner assembly

(gas fryers only)

 

pilot light

a small flame that remains burning even when the fryer is not in use; the flame

(gas fryers only)

ignites the gas when the fryer is turned on

303

G-3

Image 49
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Proper Care IntroductionAssistance Hazardous Situation WHICH, if not SafetyAVOIDED, will Result in Death or Serious InjuryPage Unpacking Instructions InstallationUnpacking Remove the counterweights from the pallet, which areInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Selecting Position and install fryer to prevent tipping or moveLocation Ment. Restraining ties may be used for stabilizationGAS Supply Ventilation of FryerFryer must be isolated from the gas supply piping During any pressure testing of the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 GAS Leak Test Regulator SettingGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components High Limit Airflow SwitchIgnition Modules Spark IgnitorsIndicators SwitchesLID Operation Melt CycleAlthough the Displaywillread Cool Switches IndicatorsDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Which could Result in Serious Burns Care ShorteningPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointFiltering of Shortening Turn COOK/PUMP switch to OFF positionSHORTENING, IT’S Possible That the Filter Cloth or Glove When TighteningConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Regular Maintenance ResetFilter Pump Motor PROTECTOR-MANUALCleaning the Nylatrons Monthly Preventive MaintenanceLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Reset Usage Special Program ModeProgramming Review UsageSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeHeat Control Special ProgramMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised