Henny Penny OFG-390 manual 303

Page 46

 

 

 

Model OFG- 390

4-2. ERROR CODES (Continued)

CE Only - Along with the error codes from page 4-2, CE

 

 

 

 

units have the following self-diagnostic error codes:

 

 

 

 

DISPLAY

CAUSE

 

PANEL BOARD CORRECTION

“E10”

Highlimit

 

Reset the high limit by manually pushing up on the red reset

 

 

 

button; if the high limit does not reset, the high limit must be

 

 

 

replaced

 

 

 

 

“E15”

Drain switch

 

Close the drain, using the drain valve handle; if display still

 

 

 

shows “E-15”, have the drain microswitch checked

 

 

 

 

“E-20A”

Air pressure

 

Press the timer button to try the ignition process again,

 

switch failure

 

and if “E-20A” persists, call Henny Penny’s Service

 

(stuck closed)

 

Department

 

 

 

 

“E-20 B”

Draft fan or

 

Press the timer button to try the ignition process again,

 

air pressure

 

and if “E-20 B” persists, call Henny Penny’s Service

 

switch failure

 

Department

 

(stuck open)

 

 

 

 

 

 

“E-20 C”

Left gas module

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 C” persists, call Henny Penny’s Service Department

 

 

 

 

“E20 D”

Rightmodule

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 D”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 E”

Both modules

 

Press the timer button to try the ignition process again, and if

 

failure

 

“E-20 E”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 F”

Left module

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 F”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 G”

Rightmodule

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 G”, persists, call Henny Penny’s Service Department

 

 

 

 

“E20 H”

Both modules

 

Press the timer button to try the ignition process again, and if

 

no flame sense

 

“E-20 H”, persists, call Henny Penny’s Service Department

 

 

 

 

4-3

303

Image 46
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Specifications Henny Penny Head GAS Open FryerTable of Contents Proper Care IntroductionAssistance AVOIDED, will Result in Death or Serious SafetyHazardous Situation WHICH, if not InjuryPage Installation Unpacking InstructionsInstructions Remove the counterweights from the pallet, which areUnpacking Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Location Position and install fryer to prevent tipping or moveSelecting Ment. Restraining ties may be used for stabilizationVentilation of Fryer GAS SupplySystem by closing its individual manual shutoff valve During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System at test pressures equal to or less than 1/2Model OFG 303 GAS Leak Test Regulator SettingGAS Pressure Electrical RequirementsModel OFG Page Operation Operating Components Ignition Modules Airflow SwitchHigh Limit Spark IgnitorsLID Operation SwitchesIndicators Melt CycleDuring the Standby MODE, the Shorten Switches IndicatorsAlthough the Displaywillread Cool ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Personal INJURY, FIRE, AND/OR Property Care ShorteningWhich could Result in Serious Burns With Prolonged USE, the FlashpointTurn COOK/PUMP switch to OFF position Filtering of ShorteningConnection AT the Union on the Filter Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Filter Pump Motor ResetRegular Maintenance PROTECTOR-MANUALCleaning the Nylatrons Monthly Preventive MaintenanceLubricating Lid Rollers -Annually Preventive MaintenancProgramming CodeAfter the proportional control, press and release Programming Special Program ModeReset Usage Review UsageFactory Presets F/C, Gas/Electric, Speaker Volume Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestHeat Control Special ProgramMode Troubleshooting Trouble Shooting Guide Problem Cause CorrectionError Codes Display Cause Panel Board Correction303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised