Model OFG- 390

3-15. PROGRAMMING

8.

After the proportional control, press and release the

(Continued)

 

FUNCTION button. “ALM 1” and “TIME” flashes in the left

 

 

side of the display, and the first alarm time shows on the right

 

 

side of the display. To change the time the alarm sounds,

 

 

press the appropriate product buttons to set the time. Ex:

 

 

Press 1,0,0,0. 10:00 flashes on the right side of the display,

 

 

which means when the timer counts down to 10 minutes, an

 

 

alarm sounds.

 

9.

After alarm is set, press and release the FUNCTION button.

 

 

“ALM 1”, “SELF-’’, and “CANCEL” flashes in the left side

 

 

of the display and “YES” or “NO” shows on the right side of

 

 

the display. The yes and no can be toggled by pressing any of

 

 

the product buttons, (l -0). “YES” means the alarm tone

 

 

automatically stops after several beeps. “NO” means some

 

 

one must manually press the appropriate product button to

 

 

stop the alarm tone.

 

10.

Repeat steps 9 and 10 for alarms 2 and 3.

 

11.

After alarm 3 is set, press and release the FUNCTION

 

 

button. “FILTER” and “CYCLES” show on the left side of

 

 

the display and the Filter Cycle value is on the right side of the

 

 

display. The value is the number of Cook Cycles that must

 

 

completed before the control signals the operator that the

 

 

shortening needs filtered.

 

12.

After the filter value is set, press and release the SELECT

 

 

FUNCTION button. “EOC” and “EXIT” flashes on the left

 

 

side of the display and “COOL” shows on the right side of

 

 

the display. The end-of-cycle, (EOC), exit point can be set

 

 

to COOL, SETP, or FITR, by pressing any of the product

 

 

buttons (EOC). At the end of a Cook Cycle the controls can

 

 

be set to return to Cool Mode, the setpoint temperature, or to

 

 

signal the operator to filter the shortening.

 

13.

After the end-of-cycle point is set, press and release the

 

 

FUNCTION button. “HEAD” flashes on the left side of the

 

 

display and a number shows on the right side of the display.

 

 

The number on the right, is the number of head of chicken to

 

 

be cooked at one time, when that product button is pressed.

 

 

The number can be changed by pressing the appropriate

 

 

product button. The control can then accumulate the head

 

 

count (usage) of that product,based on counting the number

 

 

of Cook Cycles.

703

 

3-17

Image 39
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Introduction Proper CareAssistance Injury SafetyHazardous Situation WHICH, if not AVOIDED, will Result in Death or SeriousPage Unpacking Instructions InstallationStrapped to the pallet, under the fryer Remove the counterweights from the pallet, which areUnpacking InstructionsOptional Ramp Unloading Model OFG 908 Ment. Restraining ties may be used for stabilization Position and install fryer to prevent tipping or moveSelecting LocationGAS Supply Ventilation of FryerSystem at test pressures equal to or less than 1/2 During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System by closing its individual manual shutoff valveModel OFG 303 Regulator Setting GAS Leak TestGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components Spark Ignitors Airflow SwitchHigh Limit Ignition ModulesMelt Cycle SwitchesIndicators LID OperationING is HOT and will Cause Burns Switches IndicatorsAlthough the Displaywillread Cool During the Standby MODE, the ShortenSMS Controls Filling or Adding Shortening Basic Operation Cool With Prolonged USE, the Flashpoint Care ShorteningWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering of Shortening Turn COOK/PUMP switch to OFF positionTube is not Tightened PROPERLY. if SO Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Connection AT the Union on the FilterLightingand Shutdown of the Burners Cleaning the Frypot PROTECTOR-MANUAL ResetRegular Maintenance Filter Pump MotorPreventive Maintenance Cleaning the Nylatrons MonthlyLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Review Usage Special Program ModeReset Usage ProgrammingSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeSpecial Program Heat ControlMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised