Henny Penny OFG-390 manual Tech I/O Mode, Appliance Test

Page 42

Model OFG- 390

3-16. SPECIAL PROGRAM MODE

 

(Continued)

Tech I/O Mode

 

1. Press and hold the FUNCTION button for two seconds until

 

“REG PROGRAM” shows in the display. As soon as

 

“REG PROGRAM” shows in the display, press and release

 

the FUNCTION button 4 times until “TECH I-O” shows in

 

the display.

 

2. When “CODE” shows in the display, press 2-4-6 (1-7-7-6

 

for CE units). “HEAT’, and “PUMP” shows alternately in the

 

display. Also, the LEDs over 1 and 3 flashes alternately.

 

3. To test the heat circuit, press and hold the 1 button.

 

4. To test the pump system, press and hold the 3 button.

 

To test the heat output on CE units, the blower and modules

 

must first be turned on .

 

Appliance Test

 

Press and hold the FUNCTION button for two seconds until

 

“REG PROGRAM” shows in the display. As soon as

 

“REG PROGRAM” shows in the display, press and release

 

the FUNCTION button 5 times until “APPL TEST” shows

 

in the display.

 

With the power switch on, the display will show “CURR=”,

 

along with the time it took the unit to heat from 250º to

 

300º F (121ºto 149º C) . This is normally recorded from the

 

initial heat up in the morning.

3-20

504

Image 42
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Specifications Henny Penny Head GAS Open FryerTable of Contents Introduction Proper CareAssistance AVOIDED, will Result in Death or Serious SafetyHazardous Situation WHICH, if not InjuryPage Installation Unpacking InstructionsInstructions Remove the counterweights from the pallet, which areUnpacking Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Location Position and install fryer to prevent tipping or moveSelecting Ment. Restraining ties may be used for stabilizationVentilation of Fryer GAS SupplySystem by closing its individual manual shutoff valve During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System at test pressures equal to or less than 1/2Model OFG 303 Regulator Setting GAS Leak TestGAS Pressure Electrical RequirementsModel OFG Page Operation Operating Components Ignition Modules Airflow SwitchHigh Limit Spark IgnitorsLID Operation SwitchesIndicators Melt CycleDuring the Standby MODE, the Shorten Switches IndicatorsAlthough the Displaywillread Cool ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Personal INJURY, FIRE, AND/OR Property Care ShorteningWhich could Result in Serious Burns With Prolonged USE, the FlashpointTurn COOK/PUMP switch to OFF position Filtering of ShorteningConnection AT the Union on the Filter Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Filter Pump Motor ResetRegular Maintenance PROTECTOR-MANUALPreventive Maintenance Cleaning the Nylatrons MonthlyLubricating Lid Rollers -Annually Preventive MaintenancProgramming CodeAfter the proportional control, press and release Programming Special Program ModeReset Usage Review UsageFactory Presets F/C, Gas/Electric, Speaker Volume Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestSpecial Program Heat ControlMode Troubleshooting Trouble Shooting Guide Problem Cause CorrectionError Codes Display Cause Panel Board Correction303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised