BOIL-OVER PREVENTION IN HENNY PENNY FRYERS

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SHORTENING OVERFLOWING THE FRYPOT WHICH COULD CAUSE SERIOUS BURNS, PERSONAL INJURY, FIRE AND/OR PROPERTY DAMAGE.

THE SHORTENING MAY BE STIRRED ONLY DURING THE MORNING START UP PROCEDURE. DO NOT STIR THE SHORTENINGAT ANY OTHER TIME.

FILTER THE SHORTENINGAT LEAST TWICE A DAY.

FILTER ONLY WHEN “COOL” IS DISPLAYED.

BRUSH ALL CRACKLINGS FROM FRYPOT SURFACES AND THE COLD ZONE DURING THE FILTERING PROCESS.

MAKE SURE THE FRYER IS LEVEL.

BE CERTAIN THE SHORTENING IS NEVERABOVE THE UPPER FRYPOT “FILL” LINE.

BE CERTAIN THAT THE GAS CONTROL VALVE AND BURNERS ARE PROPERLYADJUSTED. (GAS UNITS ONLY)

USE RECOMMENDED PRODUCT LOAD SIZE

FOR ADDITIONAL INFORMATION ON THESE INSTRUCTIONS, REFER TO THE HENNY PENNY OPERATOR MANUALAND THE KFC STANDARDS LIBRARY.

FOR ASSISTANCE CALLTHE HENNY PENNY SERVICE DEPARTMENTAT

1-800-417-8405.

or

1-937-456-8405

703

2-11

Image 21
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Introduction Proper CareAssistance Hazardous Situation WHICH, if not SafetyAVOIDED, will Result in Death or Serious InjuryPage Unpacking Instructions InstallationUnpacking Remove the counterweights from the pallet, which areInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Selecting Position and install fryer to prevent tipping or moveLocation Ment. Restraining ties may be used for stabilizationGAS Supply Ventilation of FryerFryer must be isolated from the gas supply piping During any pressure testing of the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 Regulator Setting GAS Leak TestGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components High Limit Airflow SwitchIgnition Modules Spark IgnitorsIndicators SwitchesLID Operation Melt CycleAlthough the Displaywillread Cool Switches IndicatorsDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Which could Result in Serious Burns Care ShorteningPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointFiltering of Shortening Turn COOK/PUMP switch to OFF positionSHORTENING, IT’S Possible That the Filter Cloth or Glove When TighteningConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Regular Maintenance ResetFilter Pump Motor PROTECTOR-MANUALPreventive Maintenance Cleaning the Nylatrons MonthlyLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Reset Usage Special Program ModeProgramming Review UsageSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeSpecial Program Heat ControlMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised