Henny Penny OFG-390 manual Preventive, Maintenanc

Page 37

 

Model OFG- 390

3-14. PREVENTIVE

Cleaning Blower Wheel - Annually

MAINTENANC

 

(Continued)

The blower wheel must be cleaned annually to ensure the unit

 

operates efficiently and without failures.

 

Make sure unit is off, and close and lock the lid.

Lid should be in locked down position. Failure to do so could result in personal injury.

2.Remove the back shroud of the unit.

3.Remove the hose from the blower housing.

On the newer fryers, the blower tube will slide out of the bracket instead of bolted. See photo below.

4.Clean the fins of the blower wheel, using a brush or straight blade screwdriver. Make sure the fins are clean of any debris.

Depending on the breading location and conditions within the kitchen area, cleaning the blower wheel may need to be done more frequently.

703

3-15

Image 37
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Proper Care IntroductionAssistance Hazardous Situation WHICH, if not SafetyAVOIDED, will Result in Death or Serious InjuryPage Unpacking Instructions InstallationUnpacking Remove the counterweights from the pallet, which areInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Selecting Position and install fryer to prevent tipping or moveLocation Ment. Restraining ties may be used for stabilizationGAS Supply Ventilation of FryerFryer must be isolated from the gas supply piping During any pressure testing of the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 GAS Leak Test Regulator SettingGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components High Limit Airflow SwitchIgnition Modules Spark IgnitorsIndicators SwitchesLID Operation Melt CycleAlthough the Displaywillread Cool Switches IndicatorsDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Which could Result in Serious Burns Care ShorteningPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointFiltering of Shortening Turn COOK/PUMP switch to OFF positionSHORTENING, IT’S Possible That the Filter Cloth or Glove When TighteningConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Regular Maintenance ResetFilter Pump Motor PROTECTOR-MANUALCleaning the Nylatrons Monthly Preventive MaintenanceLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Reset Usage Special Program ModeProgramming Review UsageSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeHeat Control Special ProgramMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised