Henny Penny OFG-390 manual Henny Penny Head GAS Open Fryer, Specifications

Page 6

HENNY PENNY

6 HEAD GAS OPEN FRYER

SPECIFICATIONS

 

Height

61" (155 cm)

Width

24" (61 cm)

Depth

41¾" ( 107 cm)

Floor Space

Approximately 7 sq. ft. (.65 sq. m.)

Pot Capacity

6 Head of chicken - 20 lbs. (9 kg.)

 

130 lbs. shortening (46 Kg.)

Electrical

120 VAC, 1 Phase, 50/60 Hz, 10 Amp, 2 Wire + Ground

 

230 VAC, 1 Phase, 50/60 Hz, 5 Amp, 2 Wire + Ground

Heating

Propane or Natural Gas; 100,000 BTU/Hr.(29.3 kw)

ShippingWeight

Approximately 670 lbs. (304 kg.)

A data plate, located on the back shroud behind the lid, gives the information of the type of fryer, serial number, warranty date, and other information pertaining to fryer. Also, the serial number is stamped on the outside of the frypot. See figure below.

703

Image 6
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Specifications Henny Penny Head GAS Open FryerTable of Contents Introduction Proper CareAssistance AVOIDED, will Result in Death or Serious SafetyHazardous Situation WHICH, if not InjuryPage Installation Unpacking InstructionsInstructions Remove the counterweights from the pallet, which areUnpacking Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Location Position and install fryer to prevent tipping or moveSelecting Ment. Restraining ties may be used for stabilizationVentilation of Fryer GAS SupplySystem by closing its individual manual shutoff valve During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System at test pressures equal to or less than 1/2Model OFG 303 Regulator Setting GAS Leak TestGAS Pressure Electrical RequirementsModel OFG Page Operation Operating Components Ignition Modules Airflow SwitchHigh Limit Spark IgnitorsLID Operation SwitchesIndicators Melt CycleDuring the Standby MODE, the Shorten Switches IndicatorsAlthough the Displaywillread Cool ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Personal INJURY, FIRE, AND/OR Property Care ShorteningWhich could Result in Serious Burns With Prolonged USE, the FlashpointTurn COOK/PUMP switch to OFF position Filtering of ShorteningConnection AT the Union on the Filter Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Filter Pump Motor ResetRegular Maintenance PROTECTOR-MANUALPreventive Maintenance Cleaning the Nylatrons MonthlyLubricating Lid Rollers -Annually Preventive MaintenancProgramming CodeAfter the proportional control, press and release Programming Special Program ModeReset Usage Review UsageFactory Presets F/C, Gas/Electric, Speaker Volume Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestSpecial Program Heat ControlMode Troubleshooting Trouble Shooting Guide Problem Cause CorrectionError Codes Display Cause Panel Board Correction303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised