3-6. BASIC OPERATION

Follow the procedure below on the initial start-up of the fryer, and

 

each time the fryer is brought from a cold, or shut down condition,

 

back into operation. These are basic, general instructions. Be sure

 

to follow KFC’s Standards Library when operating the fryer.

1.Make sure the frypot is filled with shortening to 2 the lower level indicators

DO NOT OVERLOAD, OR PLACE PRODUCT WITH EXTREME MOISTURE CONTENT INTO THE RACKS. 20 LBS. (9.0 KG.) IS THE MAXIMUM AMOUNT OF PRODUCT PER FRYPOT. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RE SULT IN SHORTENING OVERFLOWING THE FRYPOT WHICH COULD CAUSE SERIOUS BURNS, PERSONAL INJURY, FIRE AND/OR PROPERTYDAMAGE.

2.Turn the POWER/PUMP switch to the POWER position and press the appropriate product button to select the amount of product to be cooked.

The controls have a 45 second delay from when the power switch is turned on, to when the burners ignite.

All safety devices shut off the gas supply to the burner. Follow the above procedures to restart the fryer. Notify a qualified service technician if the shut down is repeated.

3.Stir the shortening as it’s heating up from a cold start. Be sure to stir down into the cold zone.

DO NOT STIR THE SHORTENINGATANY OTHER TIME EXCEPT AT MORNING START-UP. FAIL- URE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SHORTENING OVERFLOWING THE FRYPOT WHICH COULD CAUSE SERIOUS BURNS, PERSONAL INJURY, FIRE, AND/OR PROPERTYDAMAGE.

703

3-7

Image 29
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Assistance IntroductionProper Care Hazardous Situation WHICH, if not SafetyAVOIDED, will Result in Death or Serious InjuryPage Unpacking Instructions InstallationUnpacking Remove the counterweights from the pallet, which areInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Selecting Position and install fryer to prevent tipping or moveLocation Ment. Restraining ties may be used for stabilizationGAS Supply Ventilation of FryerFryer must be isolated from the gas supply piping During any pressure testing of the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 GAS Pressure Regulator SettingGAS Leak Test Requirements ElectricalModel OFG Page Operation Operating Components High Limit Airflow SwitchIgnition Modules Spark IgnitorsIndicators SwitchesLID Operation Melt CycleAlthough the Displaywillread Cool Switches IndicatorsDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Which could Result in Serious Burns Care ShorteningPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointFiltering of Shortening Turn COOK/PUMP switch to OFF positionSHORTENING, IT’S Possible That the Filter Cloth or Glove When TighteningConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Regular Maintenance ResetFilter Pump Motor PROTECTOR-MANUALLubricating Lid Rollers -Annually Preventive MaintenanceCleaning the Nylatrons Monthly Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Reset Usage Special Program ModeProgramming Review UsageSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeMode Special ProgramHeat Control Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised