Henny Penny OFG-390 manual Error Codes, Display Cause Panel Board Correction

Page 45

 

 

 

Model OFG- 390

4-2. ERROR CODES

In the event of a control system failure, the digital display shows an

 

 

error message. These messages are coded: “E04”, “E05”, “E06”,

 

 

“E32”, “E41” and “E71”. A constant tone is heard when an error

 

 

code is displayed, and to silence this tone, press any of the product

 

 

buttons.

 

 

 

 

 

DISPLAY

CAUSE

 

PANEL BOARD CORRECTION

 

 

 

“E04”

Control board overheating

Turn switch to OFF position, then turn

 

 

 

switch back to ON; if display still shows

 

 

 

“E04”, the board is getting too hot; check for

 

 

 

signs of overheating behind the control

 

 

 

panel; once panel cools down the controls

 

 

 

should return to normal; if “E04” persists,

 

 

 

have control panel replaced

 

 

 

“E05”

Shortening overheating

Turn switch to OFF position, then back to

 

 

 

ON; if display shows “E05”, the heating

 

 

 

circuits and temperature probe should be

 

 

 

checked; once the unit cools down, the

 

 

 

controls should return to normal; if “E05”

 

 

 

persists, have control panel replaced

 

 

 

“E06”

Temperature probe failure

Turn switch to OFF position, then back to

 

 

 

ON; if the display shows “E06”, the tempera-

 

 

 

ture probe should be checked; once the

 

 

 

probe is repaired, or replaced, the controls

 

 

 

should return to normal; if “E06” persists,

 

 

 

have control panel replaced

 

 

 

 

“E41”

Programmingfailure

 

Turn switch to OFF position, then back to

 

 

 

ON; if display shows “E41”, the control

 

 

 

should be re-initialized (See Programming

 

 

 

Section) if the error code persists, have control

 

 

 

panel replaced

“E71”

 

 

Pump motor relay failure or

Replace relay if contacts are stuck closed;

 

wiring problem

 

check wiring on POWER/PUMP switch, or at

 

 

 

wall receptacle; L1 and N may be reversed

“E32, FAN FAIL

 

 

Air pressure switch open; clogged

Clean dilution box or replace blower if

ERRORCHECK

dilution box or faulty blower; open

necessary; have drain switch checked; reset

BLOWER, CLEAN

drain switch; open high limit

high limit or have high limit checked

DILUTIONBOX,

 

 

 

CALLHENNY

 

 

 

PENNYSERVICE”

 

 

 

304

 

 

4-2

Image 45
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Introduction Proper CareAssistance Hazardous Situation WHICH, if not SafetyAVOIDED, will Result in Death or Serious InjuryPage Unpacking Instructions InstallationUnpacking Remove the counterweights from the pallet, which areInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Selecting Position and install fryer to prevent tipping or moveLocation Ment. Restraining ties may be used for stabilizationGAS Supply Ventilation of FryerFryer must be isolated from the gas supply piping During any pressure testing of the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 Regulator Setting GAS Leak TestGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components High Limit Airflow SwitchIgnition Modules Spark IgnitorsIndicators SwitchesLID Operation Melt CycleAlthough the Displaywillread Cool Switches IndicatorsDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Which could Result in Serious Burns Care ShorteningPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointFiltering of Shortening Turn COOK/PUMP switch to OFF positionSHORTENING, IT’S Possible That the Filter Cloth or Glove When TighteningConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Regular Maintenance ResetFilter Pump Motor PROTECTOR-MANUALPreventive Maintenance Cleaning the Nylatrons MonthlyLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Reset Usage Special Program ModeProgramming Review UsageSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeSpecial Program Heat ControlMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised