Henny Penny OFG-390 manual Gas fryers only See ignition modules

Page 50

 

Model OFG- 390

power/pump switch

a three-way switch located on the front control panel of the fryer that serves as

 

an off/on switch and a filter switch

product

a food item cooked in the fryer

rack

the wire grid that slides into the carrier to hold product during the cook cycle

setpoint

a preset cooking temperature; the setpoint is a programmable feature

shortening mixing system

an automatic system on eight head fryers hat periodically uses the filter pump to

 

mix the shortening in the frypot to prevent an accumulation of moisture to

 

minimize the boiling action in the frypot

shortening shuttle

optional equipment used for shortening disposal

sift breading

the process of removing clumps from breading

spark igniters

the igniters that create a spark to ignite the pilot lights on gas fryers

(gas fryers only)

(see ignition modules)

standpipe

the pipe through which oil is pumped back into the frypot after the filtering

 

process is complete

standpipe assembly

the pipe and fittings that are part of the shortening filtering process

straight brush

a brush that is included with the fryer that is used to clear the drain in the bottom

 

of the frypot

strip heater

keeps the filter lines free of solidified shortening when the filter heater switch is

 

turned on (Model OE-100 only)

temperature probe

a round probe that is located in the inside of the frypot that measures the

 

temperature of the oil in the frypot; the temperature probe communicates with the

 

control panel

thermal protector

overheat protection swtich for the filter motor that must be manually reset if

 

tripped

G-4

303

Image 50
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Specifications Henny Penny Head GAS Open FryerTable of Contents Assistance IntroductionProper Care AVOIDED, will Result in Death or Serious SafetyHazardous Situation WHICH, if not InjuryPage Installation Unpacking InstructionsInstructions Remove the counterweights from the pallet, which areUnpacking Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Location Position and install fryer to prevent tipping or moveSelecting Ment. Restraining ties may be used for stabilizationVentilation of Fryer GAS SupplySystem by closing its individual manual shutoff valve During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System at test pressures equal to or less than 1/2Model OFG 303 GAS Pressure Regulator SettingGAS Leak Test Electrical RequirementsModel OFG Page Operation Operating Components Ignition Modules Airflow SwitchHigh Limit Spark IgnitorsLID Operation SwitchesIndicators Melt CycleDuring the Standby MODE, the Shorten Switches IndicatorsAlthough the Displaywillread Cool ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Personal INJURY, FIRE, AND/OR Property Care ShorteningWhich could Result in Serious Burns With Prolonged USE, the FlashpointTurn COOK/PUMP switch to OFF position Filtering of ShorteningConnection AT the Union on the Filter Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Filter Pump Motor ResetRegular Maintenance PROTECTOR-MANUALLubricating Lid Rollers -Annually Preventive MaintenanceCleaning the Nylatrons Monthly Preventive MaintenancProgramming CodeAfter the proportional control, press and release Programming Special Program ModeReset Usage Review UsageFactory Presets F/C, Gas/Electric, Speaker Volume Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestMode Special ProgramHeat Control Troubleshooting Trouble Shooting Guide Problem Cause CorrectionError Codes Display Cause Panel Board Correction303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised