Henny Penny OFG-390 manual Special Program, Heat Control, Mode

Page 43

 

 

Model OFG- 390

3-16. SPECIAL PROGRAM

 

Heat Control

MODE (Continued)

1.

Press and hold the FUNCTION button for two seconds until

 

 

“REG PROGRAM” shows in the display. As soon as

 

 

“REG PROGRAM” shows in the display, press and release

 

 

the FUNCTION button 6 times until “HEAT CNTRL” shows

 

 

in the display.

 

2. When “CODE” shows in the display, press 1-2-3-4.

 

 

“MELT”, “EXIT”, and “TEMP” flashes in the display, along

 

 

with the shortening temperature at which the unit will exit the

 

 

melt cycle. This should be set at 180º F (82º C), and should

 

 

not be changed until the factory is consulted.

 

3. Press and release the FUNCTION button and ”MELT”,

 

 

“CYCLE”, and “100s” shows alternately in the display, along

 

 

with the period (pulse) length of 4000. This should not be

 

 

changed until the factory is consulted.

 

4.

Press and release the FUNCTION button twice and

 

 

“MELT”, “ON-”, “TIME”, and “100s”, shows alternately in

 

 

the display, along with the length of time the heat is on. This

 

 

should be set at 1700, and should not be changed until the

 

 

factory is consulted.

5. Press and release the FUNCTION button three times and “COOL”, “SET-”, and “POINT” shows alternately in the display, along with the temperature at which the control exits the melt cycle. This is set at 250º F (121º C), and should not be changed until the factory is consulted.

6. Press and release the FUNCTION button four times and “AUTO”, and “IDLE” shows alternately in the display, along with “OFF”. This should not be changed until the factory is consulted.

7. Press and release the FUNCITON button five times and “AUTO”, “IDLE”, and “MMSS” shows alternately in the display, along with “0:00”. This should not be changed until the factory is consulted.

8. The last 3 functions in the Heat Control Mode are used by the factory only, and should not be changed.

703

3-21

Image 43
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Henny Penny Head GAS Open Fryer SpecificationsTable of Contents Proper Care IntroductionAssistance Injury SafetyHazardous Situation WHICH, if not AVOIDED, will Result in Death or SeriousPage Unpacking Instructions InstallationStrapped to the pallet, under the fryer Remove the counterweights from the pallet, which areUnpacking InstructionsOptional Ramp Unloading Model OFG 908 Ment. Restraining ties may be used for stabilization Position and install fryer to prevent tipping or moveSelecting LocationGAS Supply Ventilation of FryerSystem at test pressures equal to or less than 1/2 During any pressure testing of the gas supply pipingFryer must be isolated from the gas supply piping System by closing its individual manual shutoff valveModel OFG 303 GAS Leak Test Regulator SettingGAS Pressure Requirements ElectricalModel OFG Page Operation Operating Components Spark Ignitors Airflow SwitchHigh Limit Ignition ModulesMelt Cycle SwitchesIndicators LID OperationING is HOT and will Cause Burns Switches IndicatorsAlthough the Displaywillread Cool During the Standby MODE, the ShortenSMS Controls Filling or Adding Shortening Basic Operation Cool With Prolonged USE, the Flashpoint Care ShorteningWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering of Shortening Turn COOK/PUMP switch to OFF positionTube is not Tightened PROPERLY. if SO Cloth or Glove When TighteningSHORTENING, IT’S Possible That the Filter Connection AT the Union on the FilterLightingand Shutdown of the Burners Cleaning the Frypot PROTECTOR-MANUAL ResetRegular Maintenance Filter Pump MotorCleaning the Nylatrons Monthly Preventive MaintenanceLubricating Lid Rollers -Annually Maintenanc PreventiveCode ProgrammingAfter the proportional control, press and release Review Usage Special Program ModeReset Usage ProgrammingSpeaker Frequency, Codes, Initialize System Factory Presets F/C, Gas/Electric, Speaker VolumeAppliance Test Tech I/O ModeHeat Control Special ProgramMode Problem Cause Correction Troubleshooting Trouble Shooting GuideDisplay Cause Panel Board Correction Error Codes303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised