Check wall
▯The walls must be smooth, vertical, and sufficiently
▯The depth of the bore holes must be the same length as the screws. The wall plugs must have a secure grip.
▯The enclosed screws and wall plugs are suitable for solid brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks).
▯The max. weight of the extractor hood is 40 kg.
Electrical connection
9WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges. The connection cable can be damaged. Do not bend or pinch connection cables during installation.
The necessary connection information is located on the identification plate in the appliance interior, remove metal grease filter to access it.
Length of the connecting cable: Approx. 1.30 m
This appliance meets EC radio interference suppression requirements.
9WARNING
Risk of electric shock
It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket that has been installed correctly. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an
Installation
Preparing the installation
9CAUTION
Ensure that there are no electric wires, gas or water pipes in the area where holes are to be made.
1Mark a vertical center line on the wall from the ceiling to the lower edge of the extractor hood.
2Mark positions for the screws and the contour of the attachment area.
3Drill five 5/16" (8 mm) Ø holes to a depth of 3 5/32" (80 mm) for the attachments and press in the wall plugs flush with the wall.
| ||
[ | ||
|
| |
|
| |
|
| PP |