APC 6000 manuals
Computer Equipment > Power Supply
When we buy new device such as APC 6000 we often through away most of the documentation but the warranty.
Very often issues with APC 6000 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Power Supply APC 6000 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Power Supply on our side using links below.
APC 6000 Installation Manual
46 pages 1.41 Mb
MGETM GalaxyTM 60003 ContentsCharacteristics Installation Appendix 4 Characteristics10 Installation(to be carried out by qualified personnel only) Handling Positioning the cubicles 11 Floor loads (figure 5)Cubicle layout on false floor or normal floor 12 Power circuit wiring diagrams16 Connection of power circuits17 160kVA to 400kVA modular UPS rectifier-inverter cubiclerear mains 1, mains 2 and load: 600 kVA single-unit UPS cubicles (see the appendix). terminals and 13 mm diameter holes. to 40 X 4 mm copper terminals and 13 mm diameter holes; battery: 250 to 300 kVA UPSs: to 65 X 4 mm copper terminals and 13 mm diameter holes, 400 kVA UPSs: to 80 X 5 mm copper mains 1, mains 2 and load: 440 mm; battery: 390 mm; front 18 250kVA to 450kVA frequency converter or parallel UPS with SSC rectifier-inverter cubicle600kVA parallel UPS cubicles (see the appendix). terminals and 13 mm diameter holes. to 40 X 4 mm copper terminals and 13 mm diameter holes; battery: 250 to 300 kVA UPSs: to 65 X 4 mm copper terminals and 13 mm diameter holes, 400 kVA UPSs: to 80 X 5 mm copper mains 1 and load: 440 mm; battery: 390 mm; front 20 500kVA modular UPS rectifier-inverter cubiclemains 1: 450 mm ; mains 2 and load: 337 mm ; battery: 385 mm ; remote relay board: 1030 mm. to 50 X 10 mm copper terminals and 12,6 mm diameter holes, and gudgeon 10 mm diameter; to 50 X 8 mm copper terminals and 5 holes of 12,6 mm diameter; to 80 X 8 mm copper terminals and 2 holes of 12,6 mm diameter. 500/800kVA Static Switch Cubiclemains 2: 1050 mm max.; inverter outputs and load: 570 mm; remote relay board: 1190 mm max. 500kVA Static Switch Cubicle: Cables connected by lugs to 80 x 5 mm 800kVA Static Switch Cubicle: Cables connected by lugs to 80 x 8 mm 22 rearfront23 1200kVA Static Switch CubicleCables connected by lugs to 80 x 8 mm copper terminals and 14 mm diametermains 2: 1310 mm; inverter outputs: 550 mm; load: 850 mm; remote relay board: 570 mm max. rearfront 26 Connection of "Media Contacts 9" standard auxiliary circuits- Connection of auxiliary circuits on the remote relay board Fig. 16recommended cable cross-section: 1 mm2 (use a shielded cable to connect the battery cell);the male connectors that fit the female connectors on the board (XR1 to XR4) are supplied;the contacts are volt-free and are shown in the diagram under the following conditions: UPS on, contact at rest;contact breaking capacity: 250V, 5A. 27 Connections between cubicles29 Connections between rectifier-inverter cubicles and external maintenance bypass cubicle30 Connection of "Media Contacts 15" additional auxiliary circuits (option) (figure 22)recommended cable cross-section: 1 mm2;the male connectors that fit the female connectors on the board (XR5 to XR9) are supplied;the contacts are volt-free and are contact breaking capacity: 250V, 5A. Connection of the battery "Temperature Monitor" (for a single-unit UPS) Connection of the battery "Temperature Monitor" (for a parallel UPS with batteries in the same room) Fig. 24 Fig. 23 31 Connection of the battery "Temperature Monitor" (optional)BC + Connectionsuse a shielded cable made up of 2 do not forget to connect the cable shield to ground pin 7 of connector XR4;in the case of a parallel UPS a "Temperature Monitor" can only be remote relay board connector XR4: 1 2 3 4 5 6 7 8 9 10 11 12 battery "Temperature Monitor"XR2 XR1 (unit shown open) shielded cable (2 twisted telephone pairs) temperature signal 12V 12V earth + 32 "Temperature Monitor" installation in a APC by Schneider Electric battery cubicle"Temperature Monitor" installation in a battery room 33 Link to an IBM AS/400 computerConnection of the "LED" remote indications unit Connection of "Tele Monitor" remote control and indication unit 34 Final installation stepsConfiguration of the AS/400 35 Appendix
Also you can find more APC manuals or manuals for other Computer Equipment.
38 pages 779.72 Kb
6739389EN/FB - Page 1 MGETM GalaxyTM 6000
Also you can find more APC manuals or manuals for other Computer Equipment.