44
ENTERING OR CHANGING YOUR (DEFAULT) ID CODE:
Enter ID menu (Repeat steps from 1 to 3).
Press d10) Display advances to CH.ID Change ID Code Submenu.
Press d11) Display shows 0000 message with flashing 1st digit.
If you want to change your default “ID Code” you can do it now,
otherwise press aand menu will skip to FULL Full Security
Submenu.
Press b& c12) Press band cbuttons to enter your new “ID Code” number.
Press d13) Display shows STRD stored message momentarily and then
advances to the FULL Full Security Submenu.
FULL SECURITY LEVEL SUBMENU:
Press d14) Display flashes ENBL Enable or DSBL Disable.
Press b
15) Scroll through the available selections: “Enable” or “Disable”.
Press d16) Display shows STRD stored message momentarily and then
advances to SP.ID Setpoint/ID Submenu.
If "Full" Security Level is "Enabled" and the user attempts to
enter the Main Menu, they will be prompted for an ID Code. The
ID Code should be correct to enter the instrument Menu item.
SETPOINT/ID SECURITY LEVEL SUBMENU:
This Security Level can be functional only if FULL Security
Level is Disabled.
Press d17) Display flashes ENBL Enable or DSBL Disable.
Press b
18) Scroll through the available selections: “Enable” or “Disable”.
Press d19) Display shows STRD stored message momentarily and then
advances to COMM Communication Submenu.
If "Setpoint/ID" Security Level is "Enabled" and the user
attempts to advance into the CNFG Configuration Menu, he will
be prompted for ID Code number. The ID Code should be
correct to proceed into the Configuration Menu, otherwise
display will show an Error and skip to the Run Mode.
If “Full” and “Setpoint/ID” Security Levels are "Disabled", the
ID code will be “Disabled” and user will not be asked for ID
Code to enter the Menu items (“ID” Submenu will not show upin
“ID/Setpoint” Menu).