Chapter 4. Applications

Table 4-C

Configuration Settings for Multi-Point Bisync Application

 

 

HOST FSU

REMOTE FSU

DTE Port 1

 

 

 

P r o t o c o l

 

BISYNC

 

BISYNC

Physical

 

CONN=RS232

 

CONN=RS232

Options

 

RATE=9600

 

RATE=9600

Protocol

 

LINE=MULTIPOINT

LINE=MULTIPOINT

Options

 

TRANS CODE= EBCDIC CRC16

TRANS CODE= EBCDIC CRC16

 

 

FORMAT=NRZ

 

FORMAT=NRZ

 

 

TIMEOUT=3

 

TIMEOUT=3

 

 

THRESHOLD=10

 

THRESHOLD=10

 

 

POLL RATIO=1

 

POLL RATIO=1

Protocol

 

ENTRY #1

ENTRY #2

ENTRY #1

Address

Table

UNIT ADDR=AA1

UNIT ADDR=BB1

UNIT ADDR=AA1

 

 

LLC2 SSAP=04

LLC2 SSAP=04

LLC2 SSAP=04

 

 

LLC2 DSAP=04

LLC2 DSAP=08

LLC2 DSAP=04

 

 

OUT DLCI=120

OUT DLCI=12

OUT DLCI=17

DTE Port 2

 

 

 

Protocol

 

BISYNC

 

BISYNC

Physical

 

CONN=RS232

 

CONN=RS232

Options

 

RATE=9600

 

RATE=9600

Protocol

 

LINE=MULTIPOINT

LINE=MULTIPOINT

Options

 

TRANS CODE= EBCDIC CRC16

TRANS CODE= EBCDIC CRC16

 

 

FORMAT=NRZ

 

FORMAT=NRZ

 

 

TIMEOUT=3

 

TIMEOUT=3

 

 

THRESHOLD=10

 

THRESHOLD=10

 

 

POLL RATIO=1

 

POLL RATIO=1

Protocol

 

ENTRY #1

ENTRY #2

ENTRY #1

Address

Table

UNIT ADDR=AA1

UNIT ADDR=BB1

UNIT ADDR=BB1

 

 

LLC2 SSAP=04

LLC2 SSAP=04

LLC2 SSAP=08

 

 

LLC2 DSAP=04

LLC2 DSAP=08

LLC2 DSAP=04

 

 

OUT DLCI=120

OUT DLCI=12

OUT DLCI=17

Frame Relay

SIGNAL TYPE=ANNEX D

SIGNAL TYPE=ANNEX D

Options

 

T391=10

 

T391=10

 

 

N391=6

 

N391=6

 

 

N392=3

 

N392=3

 

 

N393=4

 

N393=4

61200.130L1-1

FSU User Manual

29

Page 43
Image 43
ADTRAN 1200130L2, 1200130L1 user manual Configuration Settings for Multi-Point Bisync Application, Host FSU Remote FSU