Chapter 6. DTE Port Configuration
Poll/Response Timeout (TIMEOUT)
Set the amount of time the FSU waits for a poll response before issuing another poll.
Minimum Poll Timer
This parameter defines the minimum time (ms) between con- secutive polls to a given PU assigned to the DTE port.
Slow Poll Ratio (POLL RAT)
Determine how often devices on the Slow Poll list are polled. This list is automatically managed based on poll timeouts. Initially, all PUs are on the Normal list. When a PU times out a fixed number of times, it is moved to the Slow Poll list. A PU remains on this list until it responds properly to a poll.
The number entered is the number of times PUs on the Normal list are polled before PUs on the Slow Poll list are polled. Enter 1 to disable this option.
Response Timer Threshold (THRESHOLD)
Set the maximum number of response timeouts allowed before a session is terminated.
Transmit Delay (DELAY)
Set the minimum time between transmission frames.
Protocol Address Table
PU Address (PU ADDR)
Enter the physical unit address of each SDLC device you wish to connect to the FSU.
Group Address (GROUP ADDR)
Enter the address used for group polling. With this address the host can poll the FSU for information on all units connected to the FSU. This address should match the host's group address.
Set this entry to 0 to disable group polling for the DTE port.
FSU User Manual | 49 |