Chapter 7. Configuring the Network Port
Signaling Type (SIGNAL)
Set the signaling type option to match the network signaling type.
T391
Set the time between polls to the frame relay network.
N391
Determine how many link integrity polls occur in between full status polls.
N392 and N393
These parameters define the error threshold for the UNI formed by the FSU network port and the frame relay switch. If the error threshold is met, the signaling state status is changed to down, which indicates a
For example:
If N392=3 and N393= 4, then if three errors occur within any four events the interface is determined inactive.
The status of the connection can be viewed in the Status menu under Network Port Signaling State. The status will return to active again once the threshold is no longer exceeded.
Remote FECN Notification (RFECN)
Enable/disable the FSU to issue remote FECN (forward explicit congestion notification). This feature ensures that a frame will be generated in the reverse direction upon receiving a frame with the FECN bit enabled. This is a proprietary feature with ADTRAN FSUs and can only be used with an ADTRAN FSU on both ends of the virtual circuit.
The network service provider should recommend the values entered into the T391, N391, N392, and N393 fields.
FSU User Manual | 73 |