E2050:\

Configuration

Configuration Methods

This example BOOTP entry configures a hostname (hn), a hardware address (ha), and an IP address (ip) for the LAN/GPIB Gateway. All other configuration values are “set” to (will default to) the factory defaults.

E2050:\

Hostname for this Gateway

hn:\

 

ht=ether:\

Hardware type, which should be ether

vm=rfc1048:\

Vendor magic cookie selector, which should

 

be rfc1048

ha=0800091A0E00:\

Hardware address for the Gateway’s LAN

 

interface

ip=156.140.4.249

IP address for the Gateway

For each entry you make to the file, include a colon (“:”) and a backslash (“\”) after each field to continue the entry on the next line. (Do not put the :\ at the end of the last field in your entry.)

Begin the hostname with a letter. Do not start a hostname with any other character, such as a number, underscore, etc. Use only letters, numbers, periods, or hyphens within a hostname. The underscore character (“_”) is not allowed.

The LAN hardware address (ha) value is the address you recorded while installing the Gateway hardware in Chapter 2. The Gateway’s LAN hardware address is printed on a label on the underside of the Gateway box.

The IP address (ip) value is the address that your designated Network Administrator assigned for the Gateway. The address must be in dotted decimal notation.

3Once you have added the configuration values for each of your Gateways, save and close the /etc/bootptab file. Then, power on the Gateway by plugging-in the power cord to the power outlet (wall outlet).

As soon as it completes its hardware self-test, the Gateway will begin sending BOOTP requests to the BOOTP server. While the Gateway is sending BOOTP requests, the LAN Conn (LAN Connect) LED on the front panel of the Gateway will flash rapidly. The BOOTP server should respond with the BOOTP response to configure the Gateway. When the Gateway receives a valid response from the BOOTP server, the LAN Conn LED will stop flashing.