Troubleshooting

Troubleshooting Gateway Configuration

Troubleshooting Gateway Configuration

This section gives guidelines to troubleshoot E2050 LAN/GPIB Gateway configuration problems, including

nVerifying Gateway Configuration

nSetting Default Configuration

nVerifying the Configuration Method

nChanging the Configuration Method

nTroubleshooting Telnet Configuration

nTroubleshooting BOOTP Configuration

nTroubleshooting BOOTP with TFTP Configuration

Verifying Gateway Configuration

To verify that the E2050 LAN/GPIB Gateway is properly configured, you can: do the following:

nTelnet to the LAN/GPIB Gateway and use the Telnet config command to verify the current configuration settings

nTelnet to the LAN/GPIB Gateway and use the Telnet syslog- display command to see if any TFTP configuration errors were logged during the last power-on initialization of the Gateway.

nExamine the syslog file and check for configuration errors generated by the bootpd daemon or by the Gateway.

Setting Default Configuration

If you want to set the Gateway to all of its default configuration values, you can take either of the following actions. After the Gateway has been set to its default configuration values, see Chapter 3 to reconfigure the Gateway.

nPress the Config Preset button on the back panel of the E2050 LAN/GPIB Gateway at the same time that you power-on the Gateway.

nIf the Gateway is configured to a known IP address, Telnet to the Gateway and use the Telnet factory-resetcommand.