Querying the Gateway

Administration

Querying the Gateway

Querying the Gateway

This section gives guidelines to query the E2050 LAN/GPIB gateway, including:

nQuerying the Current Configuration

nQuerying the Firmware Version

nQuerying the Configuration Method

nQuerying Gateway/Client Connections

Querying the Current Configuration

As soon as you access the Gateway’s Telnet utility, you see a screen of information, including a listing of the Gateway’s current configuration settings. However, you can view the current configuration settings at any time while you are using the Telnet utility by typing config at the Telnet prompt (>).

If you want to change any of the configuration values, see “Configuring the Gateway.” If you want to exit the Telnet utility with or without saving any configuration value changes, see “Exiting the Telnet Utility”.

Querying the Firmware Revision

You may need to determine the version of the Gateway’s firmware if you contact Agilent for support information or if you need to update the firmware to a new version in the future.

To determine the current version of the Gateway’s firmware, type version at the Telnet prompt (>). You will see the version of the software and Bootrom for the Gateway, which will be similar to the following:

Software revision A.01.05

Bootrom revision A.01.03