Parallel (Centronics) Interface
The parallel port uses a standard 36-pin  Centronics connector.
Pin  | Direction  | Definition  | Pin  | Direction  | Definition  | 
  | 
  | 
  | 
  | 
  | 
  | 
1  | In  | /STROBE  | 13  | Out  | SELECT  | 
  | 
  | 
  | 
  | 
  | 
  | 
2  | In  | Data 1  | 14,15  | 
  | NC  | 
  | 
  | 
  | 
  | 
  | 
  | 
3  | In  | Data 2  | 16  | -  | Ground  | 
  | 
  | 
  | 
  | 
  | 
  | 
4  | In  | Data 3  | 17  | -  | Ground  | 
  | 
  | 
  | 
  | 
  | 
  | 
5  | In  | Data 4  | 18  | 
  | NC  | 
  | 
  | 
  | 
  | 
  | 
  | 
6  | In  | Data 5  | 19 to 30  | -  | Ground  | 
  | 
  | 
  | 
  | 
  | 
  | 
7  | In  | Data 6  | 31  | 
  | NC  | 
  | 
  | 
  | 
  | 
  | 
  | 
8  | In  | Data 7  | 32  | Out  | /Fault  | 
  | 
  | 
  | 
  | 
  | 
  | 
9  | In  | Data 8  | 33 to 36  | -  | NC  | 
  | 
  | 
  | 
  | 
  | 
  | 
10  | Out  | /ACK  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
11  | Out  | BUSY  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
12  | Out  | PE  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Auto Interface Select
The setup feature Interface Select controls the operation of interface arbitration. One of 3 settings is possible:
Parallel Only: With this setting the serial interface is ignored.
Serial Only: With this setting the parallel interface is ignored.
Auto Select: With this setting, the printer automatically arbitrates between the parallel and serial interfaces. The first interface to go active maintains active status while the other interface is held busy. After a time out period, the other interface is placed in a ready state.
Fastmark 600 Series User's Guide | 83  |