Setup Feature and Value List (continued)

Emulation Mode

[ PAL, ASCII, Hex, Display ]

Selects active emulation.

ASCII emulation is a text emulation.

 

 

 

 

Hex emulation is used for printing data in a

 

 

hexadecimal format that shows the exact

 

 

data being received by the printer.

 

 

Display emulation is similar to the HEX

 

 

emulation but print is in ASCII format. All

 

 

control codes are printed as super/subscript

 

 

characters.

 

 

PAL emulation is the native language of

 

 

the printer. This emulation must be active

 

 

to run any PAL applications.

 

 

HEX and Display are useful

 

 

troubleshooting communications or host

 

 

programming issues.

 

 

 

Date

[MM/DD/YYYY]

If the RTC is not installed this feature will

indicate NOT AVAILABLE.

 

 

 

 

If RTC option is installed, this feature

 

 

allows the date to be set. Click the Enter

 

 

button to select Month/Date/Year to

 

 

modify. Click the Display Up/Down

 

 

buttons to modify then click the Enter

 

 

button to select next parameter. When the

 

 

full date is displayed the change is

 

 

complete.

 

 

 

Time

[HH:MM:SS]

If the RTC is not installed this feature will

indicate NOT AVAILABLE.

 

 

 

 

If RTC option is installed, this feature

 

 

allows the time to be set. The hour is set in

 

 

24 hour format (0-23). Click the Enter

 

 

button to select Hour:Minutes:Seconds to

 

 

modify. Click the Display Up/Down

 

 

buttons to modify then click the Enter

 

 

button to select next parameter. When the

 

 

full time is displayed the change is

 

 

complete.

 

 

 

Daylight Savings

[Enabled, Disabled]

If the RTC is not installed this feature will

indicate NOT AVAILABLE.

 

 

 

 

If RTC option is installed, this feature

 

 

specifies whether the time is automatically

 

 

updated for Daylight Savings time.

 

 

 

Print Features

N/A

Click the Enter button to print the feature

list.

 

 

 

 

Installed PAL applications will be indicated

 

 

at the bottom of the print sample.

 

 

 

Print Test Label

N/A

Click Enter button to print a test label.

 

 

 

 

Firmware Rev.

N/A

Firmware P/N and revision

Fastmark 600 Series User's Guide