AMX MET-ECOM-D manual LCD Commands Cont, Programming, Set Disp-Brt, Get Disp-Brt, Set Disp-Cst

Models: MET-ECOM-D

1 88
Download 88 pages 17.43 Kb
Page 65
Image 65
LCD Commands (Cont.)

Programming

LCD Commands (Cont.)

SET DISP-BRT

Syntax:

Sets the brightness

"'SET DISP-BRT <tag>,< brightness level>'"

level to a percentage.

Variables:

The LCD display sup-

• brightness level # = a value from 25,50,100.

ports quad (25%), half

Example:

(50%) and full (100%)

 

brightness.

SEND_COMMAND MET1,"'SET DISP-BRIT 50’"

 

Sets the awake brightness level to 50%.

 

 

GET DISP-BRT

Syntax:

Retrieves the Bright-

"'GET DISP-BRT’"

ness level for the LCD

Example:

display.

SEND_COMMAND MET1,"'GET DISP-BRT’"

 

 

Returns:

 

DIS-BRT=50

 

 

SET DISP-CST

Syntax:

Sets the display con-

"'SET DISP-CST <Contrast Level>'"

trast.

Variables:

 

 

• Contrast Level = a value from 0 - 255.

 

Example:

 

SEND_COMMAND MET1,"'SET DISP-CST 128'"

 

Sets the display contrast to approximately 50%.

 

 

GET DISP-CST

Syntax:

Retrieves the contrast

"'GET DISP-CST <Contrast Level>'"

setting for the LCD dis-

Example:

play.

SEND_COMMAND MET1,"'GET DISP-CST’"

 

 

Returns:

 

DISP-CST 50

 

 

SET DISP-STATE

Syntax:

Sets the display state

"'SET DISP-STATE <tag>’"

on/off.

Variables:

 

 

• Tag = ON turns display on, OFF turns display off

 

Example:

 

SEND_COMMAND MET1,"'SET DISP-STATE ON’"

 

Sets the display on

 

 

GET DISP-STATE

Syntax:

Retrieves the display

"'GET DISP-STATE’"

state for the LCD dis-

Example:

play.

SEND_COMMAND MET1,"'GET DISP-STATE’"

 

 

Returns:

 

ON

 

 