Using the Configuration Manager
Configuration Page - NetLinx Settings Tab
Select the NetLinx Settings tab of the Configuration page to access the NetLinx Settings tab (FIG. 33).
Use the options in this tab to view and edit the ICSP connection to the NetLinx master.
FIG. 33 Configuration Page - NetLinx Settings tab
Configuration Page - NetLinx Settings Tab
Connection | Displays the ICSP connection status (Not Connected / Connected). |
|
|
Mode | Master connection mode: |
| • URL(TCP) - The device connects to the specific IP/URL of a master via a TCP |
| connection. |
| • Auto - The device connects to the first master that responds. This setting requires you |
| set the System Number. |
| • Listen - The device "listens" for the master to initiate contact. This setting requires you |
| provide the master with the device’s IP. |
|
|
System Number | The ICSP system number. |
|
|
Device Number | The ICSP device number. |
|
|
Master IP/URL | IP or URL of master for URL master connection mode |
|
|
Master Port Number | The ICSP socket port number. |
|
|
Username | The ICSP network username (required if the NetLinx master is encrypted). |
|
|
Password | The ICSP network password (required if the NetLinx master is encrypted). |
|
|
Friendly Name | The friendly name of the device as it appears in the NetLinx master connection tree. |
|
|
Setting the ICSP Connection to the NetLinx Master
1.In the Configuration page, select the NetLinx Settings tab.
2.Enter the system number assigned to the ICSP system.
3.Enter the device number to be assigned to the Metreau Entry Communicator in the Device Number field.
4.Enter the IP address of the master that the Metreau Entry Communicator is to connect with in the Master IP/URL field.
Metreau Entry Communicators | 39 |
|
|