AMX MET-ECOM-D manual Creating Intercom Pages, Ending a Doorbell Call, Advanced Setup page

Models: MET-ECOM-D

1 88
Download 88 pages 17.43 Kb
Page 78
Image 78
Ending a Doorbell Call

Using the NetLinx Module

The options in this page allow you see and view the incoming doorbell call, as well as adjust the microphone and speaker volume levels for both the doorbell and the panel.

Door Microphone Level - Use the Up/Down arrow buttons to raise/lower the doorbell’s microphone level. The current microphone level for the doorbell is indicated in the bargraph. Press the Mute button to mute the doorbell microphone.

Door Speaker Level - Use the Up/Down arrow buttons to raise/lower the doorbell’s speaker level. The current speaker level for the doorbell is indicated in the bargraph. Press the Mute button to mute the doorbell speaker.

Panel Microphone Level - Use the Up/Down arrow buttons to raise/lower the panel’s microphone level. The current microphone level for the panel is indicated in the bargraph. Press the Mute button to mute the panel microphone.

Panel Speaker Level - Use the Up/Down arrow buttons to raise/lower the panel’s speaker level. The current speaker level for the panel is indicated in the bargraph. Press the Mute button to mute the panel speaker.

The Doorbell Mute buttons only perform mute. They do not perform un-mute.

Ending a Doorbell Call

Press the End Call button in the Someone At The Door page to terminate the intercom session with the doorbell.

Creating Intercom Pages

The easiest method of creating your own intercom pages is to start with the pages provided by AMX in the module. You can change the aesthetics of the pages as long as the channel, address, level and links remain untouched.

For the more ambitious panel designers, the necessary intercom directory buttons and their information are contained in the Sample Intercom Page table on page 74.

Advanced Setup page

Advanced Setup

Name

Description

Channel

Address

 

 

Port:Code

Port:Code

 

 

 

 

Allow Panel to be

Toggle the panel’s ability to be monitored off and on.

1:11

 

Monitored

 

 

 

 

 

 

 

Allow Panel to

Toggle the panel’s ability to monitor off and on.

1:10

 

Monitor

 

 

 

 

 

 

 

Room Name

The name of the panel as it appears in other intercom

 

0:265

 

directories. See Naming a panel section on page 70.

 

 

 

 

 

 

Name Panel

Set the name of the panel as it appears in other intercom

0:334

0:265

 

directories. (G4 Web Control: Server Name)

 

 

 

 

 

 

Back

Navigates the intercom panel to the intercom Setup page. This

 

 

 

requires a standard page flip to Setup.

 

 

 

 

 

 

72

Metreau Entry Communicators

Page 78
Image 78
AMX MET-ECOM-D manual Creating Intercom Pages, Ending a Doorbell Call, Advanced Setup page