Anritsu manual System Description, General Information, ME7840A OMM, DRA Scorpion

Models: ME7840A

1 126
Download 126 pages 42.52 Kb
Page 16
Image 16
SYSTEM DESCRIPTION

GENERAL INFORMATION

SYSTEM DESCRIPTION

Table 1-1.Test Set Configurations

Model

Frequency Range

Max AUT Power Output

Reverse Measurements

Circulator

(MHz)

(Watts)

(S22, Hot S22, S12 Possible)

(at AUT Output Path)

 

 

 

 

 

 

MS4782A

800 to 1000

50

Yes

Internal

 

 

 

 

 

MS4782D

800 to 2400

100

Yes

External

 

(Note 1)

(Note 2)

 

 

 

 

 

 

 

Notes:

1.This frequency range does not account for any restricting effects caused by use of external circulator.

2.This Max AUT power assumes a minimum isolation of 23 dB provided by external circulator(s). Two circulators may have to be used to provide the required isolation.

1-9SYSTEM

Brief descriptions of the DRA Scorpion (MS462XC) and MS4782X Test

DESCRIPTION

Set are given below.

DRA Scorpion

The Scorpion Direct Receiver Access (DRA) version Vector Network Mea-

 

surement System (VNMS) (Figure 1-2)functions under control of the soft-

 

ware residing in the PC through GPIB commands. The software supports

 

tuning and alignment operations by generating real time graphic displays

 

of the measured data on the PC screen.

 

Under software control, 3rd, 5th and 7th order IMD products can be mea-

 

sured and displayed. Also, the Upper and Lower Side Band (USB & LSB)

 

components of the IMD products are measured and displayed separately.

 

The DRA Scorpion includes the following capabilities:

 

 

￿ Two internal, independent RF sources. Each source has a range of

 

 

–15 dBm to +10 dBm. A 0dB to 70dB step attenuator (10 dB / step)

 

 

is provided for each source resulting in a Power Output range of

 

 

–85 dBm to +10 dBm from each source.

 

 

 

 

 

NOTE

 

 

After test set losses, the maximum net power at the input of the amplifier

 

 

under test (AUT) is +5 dBm.

 

 

 

 

 

￿ Complete built-in capability for IMD measurements. A combiner is

 

 

provided in the Test Set.

 

 

￿ Internal Transfer Switch enabling S22 and Hot S22 measurements.

 

 

The reflectometer set-up is provided in the Test Set.

 

 

￿ Direct access to each of the four receiver channels (two reference

 

 

channels and two test channels) for maximum flexibility in measur-

 

 

ing forward and reverse S-parameters over a wide range of AUT

 

 

output power. The Test Set provides incident and reflected signal

 

 

separation.

ME7840A OMM

1-5

Page 16
Image 16
Anritsu manual System Description, General Information, ME7840A OMM, DRA Scorpion