5-5S-PARAMETER TESTS:

This test measures the scattering parameters (S-parameters). The test

S21, S11, S22, S12, ALL

module comprises six tests: S11, S12, S21, S22, and ALL. (The K Factors

 

test is described in paragraph 5-6.) In each case, the measurement

 

 

screens are the similar. This procedure will present a test screen for the

 

“S21” measurement and will describe certain differences at the end of the

 

procedure.

 

 

 

 

 

Procedure.

 

 

 

 

 

 

Prepare the ME7840A as shown in Chapter 3.

 

 

Enter the appropriate test values in the displayed

 

 

User Input screen. The input fields are described

 

 

below: The inputs required for this test are de-

 

 

scribed below.

 

 

 

 

 

 

￿ S-Parameter:Drop down options. Set to S21 for

 

 

this procedure. Other selections include S11, S12,

 

 

S22, ALL, and K Factor (paragraph 5-6).

 

 

 

￿ Data Points: Drop down options ￿ number of data

 

 

points in frequency sweep.

 

 

 

￿ Frequency 1 (MHz): Lower frequency or start fre-

 

 

quency.

 

 

 

 

 

 

￿ Frequency 2 (MHz): Upper frequency or stop fre-

 

 

quency.

 

 

 

 

 

 

￿ Input Power (dBm):Input power level, in dBm.

 

 

￿ IF Bandwidth (Hz):Intermediate frequency band-

 

 

width for test, in Hertz.

 

 

 

 

 

￿ Test Set Setting: Byte value for setting test set

 

 

attenuation and source switch (below).

 

 

 

 

 

 

 

 

 

 

 

 

Internal Source

Value

External Source

 

Value

 

 

 

 

 

 

 

 

 

 

 

0 dB

8

0 dB

 

0

 

 

 

 

 

 

 

 

 

 

 

10 dB

9

10 dB

 

1

 

 

 

 

 

 

 

 

 

 

 

20 dB

10

20 dB

 

2

 

 

 

 

 

 

 

 

 

 

 

30 dB

11

30 dB

 

3

 

 

 

 

 

 

 

 

 

 

 

40 dB

12

40 dB

 

4

 

 

 

 

 

 

 

 

 

 

 

50 dB

13

50 dB

 

5

 

 

 

 

 

 

 

 

 

 

 

60 dB

14

60 dB

 

6

 

 

 

 

 

 

 

 

 

 

 

70 dB

15

70 dB

 

7

 

 

 

 

 

 

 

 