Problem

Solution

 

 

Unable to perform a GET

1. Verify the read (GET) community name.

 

2. Use the Control Console or Web interface to ensure

 

that the NMS has access. See Telnet/SSH.

 

 

Unable to perform a SET

1. Verify the read/write (SET) community name.

 

2. Use the control console or Web interface to ensure

 

that the NMS has write (SET) access. See Telnet/

 

SSH.

 

 

Unable to receive traps at

Query the MIB mconfigTrapReceiverTable OIDs to

the NMS

verify that the NMS IP address is listed correctly, and

 

that the community name defined for the NMS matches

 

the community name in the table. If necessary, use SETs

 

to the OIDs, or use the control console or Web interface

 

to correct the trap receiver definition problem. See

 

Telnet/SSH.

 

 

Traps received at an NMS

See your NMS documentation to verify that the traps are

are not identified

properly integrated in the alarm/trap database.

 

 