68DSR Switch Installer/User Guide
2.To disable Full Screen mode, click the Full Screen Mode button on the floating toolbar to return to the desktop window.
To enable full or manual scaling:
To enable full scaling, select View - Scaling from the Video Viewer window menu. The device image scales automatically to the resolution of the server being viewed.
To enable manual scaling, select View - Scaling from the Video Viewer window menu. Choose the dimension to scale the window. Available manual scaling sizes are as follows:
1024 x 768 | 768 x 576 |
960 x 720 | 704 x 528 |
896 x 672 | 640 x 480 |
832 x 624 |
|
Adjusting color depth
The Dambrackas Video Compression® (DVC) algorithm enables users to adjust the number of viewable colors in a remote session window. You can choose to display more colors for the best fidelity or fewer colors to reduce the volume of data transferred on the network.
Video Viewer windows can be viewed using the Best Color Available (slower updates), Best Compression (fastest updates), a combination of Best Color and Best Compression or in Grayscale.
You can specify the color depths of individual ports and channels by selecting the View - Color command in a remote session window. These settings are saved individually per channel.
Additional video adjustment
Generally, the Video Viewer window automatic adjustment features optimize the video for the best possible view. However, users can
Users can also verify the level of packets per second required to support a static screen by observing the packet rate located in the lower
To manually adjust the video quality of the window:
NOTE: The following video adjustments should be made only on the advice and with the help of Avocent Technical Support.
1.Select Tools - Manual Video Adjust from the Video Viewer window menu.
Click the Manual Video Adjust button.
The Manual Video Adjust dialog box appears. Figure 5.2 shows the dialog box, and descriptions follow in Table 5.2.