To set the deliming interval:

Maintenance

Deliming

To set the deliming interval:

1.Remove power from the appliance.

2.Remove the two screws located on the side panel. Slide the control module forward. See Figure 12.

3.Turn the potentiometer to the required setting. See Figure 13.

4.Slide the control back in, replace the two screws.

5.Apply power to the appliance.

A PC may be connected at power up of the ap- pliance to verify the potentiometer setting. The “De- liming interval is x hour(s) of steam generator run time.” Status line will show 30, 60 or 90. Refer to Figure 15 on page 29.

Figure 13

Setting C

Setting B

Setting A

TP4

Potentiometer Settings

Figure 14

Figure 12