This shutdown alarm is indicated by Low Oil Pressure on the digital display. The unit is equipped with an oil pressure switch that uses normally closed contacts held open by engine oil pressure during operation. Should oil pressure drop below the 8 psi range, switch contacts close and the engine will shut down.
To remedy the low oil pressure condition, add the recommended oil to the FULL mark on the dipstick or contact your installer or an authorized dealer.
High Coolant Temperature
This shutdown alarm is indicated by High Coolant Temperature on the digital display. This condition occurs when the temperature of the coolant exceeds the shutdown threshold.
To remedy the problem, contact your installer or an authorized dealer.
External Shutdown 1,2 or 3This shutdown alarm is indicated by External Shutdown on the digital display.
To remedy the problem, contact your installer or an authorized dealer.
This shutdown alarm is indicated by Generator CCW on the digital display. This condition occurs when the generator phase is out of sequence.
To remedy the problem, contact your installer or an authorized dealer.
Start FailThis shutdown alarm is indicated by Start Fail on the digital display. This condition occurs when the generator does not start.
To remedy the problem, contact your installer or an authorized dealer.
Stop FailThis shutdown alarm is indicated by Stop Fail on the digital display. This condition occurs when the generator fails to stop.
To remedy the problem, contact your installer or an authorized dealer.
Battery Flat
|
|
| This shutdown alarm is indicated by Battery Flat on the digital | |
Generator Circuit Breaker (GCB) Fail | display. This condition occurs if the controller loses power | |||
This shutdown alarm is indicated by GCB Fail on the digital | during starting sequence due to a bad battery condition. It will | |||
not try to start again until the battery is functioning properly. | ||||
display. This condition occurs when the generator circuit | To remedy the problem, contact your installer or an | |||
breaker trips or becomes |
| |||
| authorized dealer. | |||
To remedy the problem, contact your installer or an | ||||
| ||||
authorized dealer. |
|
| Voltage Autodetect | |
|
|
| ||
Generator Overvoltage |
|
| This shutdown alarm is indicated by Voltage Autodetect on | |
This shutdown alarm is indicated by Generator Overvoltage | the digital display. This condition occurs if the controller | |||
loses power during starting sequence due to a bad battery | ||||
on the digital display. This condition occurs when the output | condition. It will not try to start again until the battery is | |||
voltage exceeds the preset threshold. |
| functioning properly. | ||
To remedy the problem, contact your installer or an | ||||
| ||||
authorized dealer. | NOT |
| To remedy the problem, contact your installer or an | |
|
| authorized dealer. | ||
|
|
| ||
Generator Undervoltage |
|
| ||
This shutdown alarm is indicated by Generator Undervoltage |
| |||
on the digital display. This condition occursforwhen the output |
| |||
voltage drops below the preset threshold. |
|
| ||
To remedy the problem, contact your installer or an |
| |||
authorized dealer. |
| REPRODUCTION |
This shutdown alarm is indicated by Generator Overfrequency on the digital display. This condition occurs when the generator frequency is out of limits given by setpoints.
To remedy the problem, contact your installer or an authorized dealer.
Generator UnderfrequencyThis shutdown alarm is indicated by Generator Underfrequency on the digital display. This condition occurs when the generator frequency is out of limits given by setpoints.
To remedy the problem, contact your installer or an authorized dealer.