WARNING Generator produces hazardous voltage.

 

WARNING Propane and Natural Gas are extremely

 

Failure to properly ground generator could result

 

flammable and explosive, which could cause

 

in electrocution.

 

burns, fire or explosion resulting in death or

 

Failure to isolate generator from utility power could

 

serious injury.

 

result in death or serious injury to electric utility

Install the fuel supply system according to NFPA 37 and

 

workers due to backfeed of electrical energy.

 

other applicable fuel-gas codes.

DO NOT touch bare wires or bare receptacles.

Before placing the generator into service, the fuel system

DO NOT use generator with electrical cords which are

 

lines must be properly purged and leak tested.

 

worn, frayed, bare or otherwise damaged.

After the generator is installed, you should inspect the fuel

DO NOT handle generator or electrical cords while

 

system periodically.

 

standing in water, while barefoot, or while hands or feet

NO leakage is permitted.

 

are wet.

DO NOT operate engine if smell of fuel is present or other

• If you must work around a unit while it is operating,

 

explosive conditions exist.

 

stand on an insulated dry surface to reduce the risk of a

DO NOT smoke around the generator. Wipe up any oil

 

shock hazard.

 

 

spills immediately. Ensure that no combustible materials

DO NOT allow unqualified persons or children to operate

 

 

are left in the generator compartment. Keep the area near

 

or service generator.

 

the generator clean and free of debris.

In case of an accident caused by electrical shock, immediately shut down the source of electrical power and

 

contact the local authorities. Avoid direct contact with

 

WARNING Exhaust heat/gases could ignite

 

 

 

 

 

REPRODUCTIONline to generator. DO NOT use with or substitute any other

 

the victim.

 

 

 

combustibles or structures resulting in

Despite the safe design of the generator, operating this

 

death or serious injury.

 

equipment imprudently, neglecting its maintenance or

 

Contact with muffler area could cause

 

being careless could cause possible injury or death.

 

burns resulting in serious injury.

Remain alert at all times while working on this equipment.

DO NOT touch hot parts and AVOID hot exhaust gases.

 

Never work on the equipment when you are physically or

Allow equipment to cool before touching.

 

mentally fatigued.

 

Exhaust outlet side of weatherproof enclosure must

Before performing any maintenance on the generator,

 

have at least 5 ft. (1.5m) minimum clearance from any

 

disconnect the battery cable indicated by a NEGATIVE,

 

structure, shrubs, trees or any kind of vegetation.

 

NEG or (-) first. When finished, reconnect that cable last.

Standby generator weatherproof enclosure must be at

After your system is installed, the generator may crank

 

least 5 ft. (1.5m) from windows, doors, any wall opening,

 

shrubs or vegetation over 12 inches (30.5 cm) in height.

 

and start without warning any time the e is a power

 

 

 

 

 

 

for

Standby generator weatherproof enclosure must have a

 

failure. To prevent possible injury, always set the

 

generator’s system switchNOTto OFF, rem ve the service

 

minimum of 5 ft. (1.5 m) overhead clearance from any

 

disconnect from the disconnect b x AND remove the

 

structure, overhang, or trees.

 

15 Amp fuse BEFORE working on the equipment.

DO NOT place weatherproof enclosure under a deck or

 

 

 

 

 

 

 

other type of structure that may confine airflow.

 

 

 

 

 

 

Use only flexible fuel line provided. Connect provided fuel

 

WARNING Hazardous Voltage - Contact with power

 

 

 

 

 

 

 

lines could cause electric shock or burns,

 

flexible fuel line.

 

 

 

 

resulting in death or serious injury.

 

 

 

 

 

Smoke detector(s) MUST be installed and maintained

 

 

 

 

Lifting Hazard / Heavy Object - Could result

 

 

 

 

 

 

 

 

in serious injury.

 

 

indoors according to the manufacturer’s instructions/

• If lifting or hoisting equipment is used, DO NOT contact

 

recommendations. Carbon monoxide alarms cannot

 

any power lines.

 

 

detect smoke.

DO NOT lift or move generator without assistance.

Keep at least minimum distances shown in General

DO NOT lift unit by roof as damage to generator

 

Location Guidelines to insure for proper generator cooling

 

and maintenance clearances.

 

will occur.

 

 

 

 

 

 

Replacement parts must be the same and installed in the

 

 

 

 

 

 

 

 

 

 

 

 

 

same position as the original parts.

5