General Configuration Screen

!

CAUTION

When the COM port is configured to perform the UPS application, all future Local Management connections must be made by establishing a Telnet connection to the device. Ensure that the device has a valid IP address before saving changes to the COM port application. If the device does not have a valid IP address and the changes are saved, refer to Appendix C for instructions on clearing NVRAM in order to reestablish COM port communications.

5.7.11 Clearing NVRAM

Clearing NVRAM will result in the loss of all user-entered

!parameters. Do not proceed unless this procedure is

CAUTION

completely understood.

 

Clearing NVRAM allows the user to clear all user-entered parameters, such as, the IP address and Community Names from NVRAM.

Clear NVRAM as follows:

1.Use the arrow keys to highlight the Clear NVRAM field.

2.Use the SPACE bar to toggle the field to YES.

3.Use the arrow keys to highlight SAVE at the bottom of the screen.

4.Press ENTER. The warning screen shown in Figure 5-14displays.

2E42-27/2E42-27R/2E43-27/2E43-27R User’s Guide

5-29

Page 81
Image 81
Cabletron Systems 2E43-27R, 2E42-27R manual Clearing Nvram