| No Display on Control Unit after Power ON. (1) |
|
|
|
|
|
| ||
|
| Check Method of Causes | Repair Method | Explanation Figures |
Check the power is available at the wall socket before proceeding to |
| Normal for 14V thru 19V |
|
|
|
| |
checking of causes. |
|
|
|
[1] Checking the AC Adapter |
| Red Cable | |
|
| ||
1. Detach the plug of AC adapter from the AC adapter inlet of the |
| DC Connector |
|
main unit. |
|
|
|
2. Connect the wall socket plug of the AC adapter to the wall |
|
|
|
socket. |
|
| Cable Connector |
|
|
| |
3. Using a tester, measure the voltage at the plug which will be |
|
|
|
connected to the main unit. (Fig. 1) |
| Black Cable |
|
t The AC adapter will be working fine, if the voltage is minus |
|
| |
|
|
| |
|
|
| |
connector and also the meter reading is in the range of 14V |
|
|
|
and 19V. | Fig. 1 |
| Fig. 2 |
t When the measured voltage is 0V, or less than 14V, the |
| ||
Replace the AC adapter. | Normal for 14V thru 19V | ||
AC adapter will be defective. |
| ||
Note: Never |
|
|
|
damage the AC adapter. |
| Black Cable | Red Cable |
[2] Checking the Wiring within the Frame |
| ||
|
|
| |
1. When the AC adapter is found to be correct, proceed to |
|
|
|
checking of wiring within the frame. Loosen the four screws |
|
| Terminal |
on the handlebar stem to remove the control unit. (Fig. 2) |
|
| |
|
| 3 (+) | |
|
|
| |
2. Remove the 5P cable which is connected to the back of the |
|
|
|
control unit. (Fig. 2) |
|
|
|
3. Connect the AC adapter, and turn on the main unit. |
| 5P Cable |
|
|
|
|
4. Using a tester, measure the voltage across the terminals 1 |
| Terminal 1 |
and 3 (+) of the 5P cable. (Fig. 3) |
| |
|
| |
t The main unit side will be working fine if the meter reading | Replace the control unit. | Fig. 3 |
is in the range of 14V and 19V. This means the control unit |
|
|
will be defective. |
|
|
Cateye Ergociser Series 1000 Service Manual
T-1 No Display on Control Unit after Power ON. (1)
11