Applicable Models: EC-1200 EC-1600 EC-3600 EC-3700

MS-7Replacing the Idler Set

1. Remove the frame cover by referring to the Sections D-1 & D- 2 "Removing the Frame Covers."

2. Remove the idler spring from the pawl of the idler metal base. (Fig. 1)

3. Loosen the idler mounting bolts, and detach the idler set. (Fig. 2)

4. Mount a brandnew idler set by using an idler mounting bolt.

5. Hang the idler spring on the pawl of the idler to give tension to the belt.

Idler Set

EC-1200 & EC-1600

Idler Set

EC-3600 & EC-3700

Idler

Idler

Idler Fixing

Bolt

Idler Spring

Fig. 1

Fig. 2

Cateye Ergociser Series 1000 Service Manual

MS-7Replacing the Idler Set

43

Page 45
Image 45
Cateye EC-3600, EC-3700 service manual MS-7Replacing the Idler Set