Applicable Models: EC-1200 EC-1600 EC-3600 EC-3700

T-5

No Loading (Check of Electrical Systems)

 

 

 

Check Method of Causes

Repair Method

Explanation Figures

[2]Checking the Electrical Systems

 

Power Supply Board

 

 

 

1. Connect the AC adapter, and turn on the power of the main unit.

2. Obtain the manual training program, set the pedal torque setting to 4.0kg·m, and rotate the pedal at the rate of 50 rpm. If you can rotate it quite easily, no load will be applied.

3. Replace the control unit with a brand new one.

4. Again, check the torque status under the manual training

 

 

program.

 

 

t When the pedal torque is loaded, the control unit is

Replace the control unit with a brand new one.

 

defective.

 

CN-2 Connector

 

 

When no torque loading is possible, proceed to the following

Fig. 1

Fig. 2

procedures.

Normal when zero (0)

 

1. Turn off the power, and loosen the four screws on the

 

 

 

handlebar stem to remove the control unit. (Fig. 1)

 

 

2. Remove the cable connector which is connected to the back of the control unit. (Fig. 1)

3. Remove the frame cover. (See the Sections D1 & D2 "Removing the Frame Covers.")

4. Remove the CN-2 connector on the power supply board. (Fig. 2)

5. Using a tester, check for any short-circuiting across Terminal

 

 

 

1s and Terminal 4s at both ends of the 5P cable which

 

 

 

connects the power supply board and the control unit. (Fig. 3)

 

Connector

CN-1 Connector

t When there is no shortcircuit, the 5P cable is disconnected.

 

Replace the 5P cable with a brand new one. (See the

Terminal 4

 

 

Fig. 4

When it is short-circuited, proceed to the following procedures:

Section ES-2 " Replacing the 5P Cable.")

 

 

5P Cable

 

1. Remove the connector CN-1 from the power supply board,

 

Connector Terminal 4

 

 

and measure the resistance across Terminals 2 and 3 of the

 

Fig. 3

 

connector. When the reading is in the range of 9Ω and 14Ω,

 

 

 

the connector is all right. (Figs. 4 & 5)

 

Normal for 14V thru 19V

 

t When the meter reading is exceedingly large, the solenoid

 

 

Replace the workload unit. (See the Sections MS-1 &

 

 

coil is defective.

MS-2 "Replacing the Workload Unit.")

 

 

t When the meter reading is in the acceptable range, the

Replace the power supply board. (See the Section

 

 

power supply board may be defective.

ES-3 "Replacing the Power Supply Board.")

 

 

 

 

 

Connector

 

 

 

Terminal 2

 

 

 

To Solenoid Coil

 

 

Connector Terminal 3

 

 

 

 

CN-1 Connector

 

 

Fig. 5

 

Cateye Ergociser Series 1000 Service Manual

T-5No Loading (Check of Electrical Systems)

17

Page 19
Image 19
Cateye EC-3600, EC-3700 service manual 5No Loading Check of Electrical Systems, Section ES-2 Replacing the 5P Cable