Chapter 2 Cabling the CSS
Troubleshooting CSS Hardware Components
Troubleshooting the Console Interface
Table
•Baud Rate - 9600
•Data Bits - 8
•Flow Control - none
•Parity - none
•Stop Bits
For information on console cable pinouts, see Appendix B, Cable Pinouts.
Table
Possible Problem | Recommended Action |
|
|
Nothing appears on the screen. | Ensure the |
| connected to the console port. |
|
|
Characters appear on the screen, but | Verify that the CSS and the console |
are garbled. | settings match for baud rate, data bits, |
| stop bits, and parity. |
|
|
Abbreviated input is used, but pressing | Ensure that you enter enough |
the tab key does not enter the command | characters for the CSS to distinguish |
you want. | between different commands and |
| options. |
|
|
Random characters are lost. | Set the flow command on the console |
| to XON/XOFF. |
|
|
|
| Cisco 11000 Series Content Services Switch Hardware Installation Guide |
|
|
|
|
| ||
|
|
| ||
|
|
|