Cisco Systems 11000 Series manual Troubleshooting the CSS 11800 Modules, 2-37

Models: 11000 Series

1 122
Download 122 pages 32.92 Kb
Page 85
Image 85
Troubleshooting the CSS 11800 Modules

Chapter 2 Cabling the CSS

Troubleshooting CSS Hardware Components

Note Installing a second CSS 11800 power supply provides power load balancing between the two power supplies. When you install a second power supply, it powers on and begins to share the power load automatically.

Troubleshooting the CSS 11800 Modules

Each CSS 11800 module is equipped with a temperature sensor that detects an over- or under-temperature condition. If the module detects that its temperature is out of range, it generates a log message.

Module status is indicated by the Status LED on the module front panel. For information about the module LEDs, see the module information earlier in this chapter.

Table 2-15 provides suggestions for correcting problems that may occur with the modules.

Table 2-15 Troubleshooting the CSS 11800 Modules

Symptom

Recommended Action

 

 

System cannot identify

Remove the module and re-install it to reseat the

module type.

module in the backplane connector.

 

 

 

Reload the ADI file.

 

 

System cannot find an image

Reload the ADI file.

for the module.

 

 

 

Module failed diagnostic

Replace the module.

(according to the

 

information in the Boot.log

 

file).

 

 

 

 

 

Cisco 11000 Series Content Services Switch Hardware Installation Guide

 

 

 

 

 

 

78-15146-02

 

 

2-37

 

 

 

Page 85
Image 85
Cisco Systems 11000 Series manual 2-37, 15 Troubleshooting the CSS 11800 Modules