Installation Guide
54 October 2007
2. In the From fields in the Interval pane on the right, enter the beginning date
and time for the historical call reference period.
3. In the To fields, enter the ending date and time for the historical call
reference period.
4. Highlight the first three statistics queries in the Statistics pane as shown in
Figure 20.
5. Select the Use 30 Minutes Interval check box.
6. Enter the following directory path in the Directory field:
C:\Program Files\Cisco\WFO_WFM\reports
7. S ele ct th e Un if ie d C CX DSN from the DSN field.
8. Enter the Unified CCX user ID and password.
9. Click Test Connection to verify the connection is working.
10. Click Go to capture the historical call data. The reports are created and saved
to the folder C:\Program Files\Cisco\WFO_WFM\reports.
11. When the hourglass disappears, click Quit to exit the Capture Agent dialog.
12. Choose Collector > Quit to exit Odysoft ODBC Collector.
Verifying Historical Call Data Capture
When you finish capturing the historical call data, the capture module processes the
reports in the folder C:\Program Files\Cisco\WFO_WFM\reports and moves them to
the folder C:\Program Files\Cisco\WFO_WFM\archives.
The historical call data capture is complete when there are no more reports in the
folder C:\Program Files\Cisco\WFO_WFM\reports.