3.4 Panel LED Indicators

1) Power (POWER) LED: Green

On:

Power is stable.

Off:

Power is not stable.

2) Paper roll end (PAPER OUT) LED: Red

On:

The paper roll near end is detected.

Off:

Paper is loaded (Normal condition)

Blinking: Self-test standby state (refer to Section 3.5.3) or macro standby state

Macro execution standby state when the macro execution command is used.

Table 3.4.1 Standby State Indication

State

PAPER LED Blinking Pattern

Recovery Conditions

Waiting for self-test printing

PAPER OUT

Pressing the FEED button

to be continued or macro

 

 

 

 

Approximately 320 ms

causes self-test printing to be

 

 

 

 

execution ready state.

 

 

 

 

continued or executes the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

macro.

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: A macro can be executed r times (r specifies the number of times to execute the macro) within the specified definition range. The macro can be executed continuously or can be executed by pressing the button. If the macro is executed by pressing the FEED button, the PAPER OUT LED blinks to indicate the macro execution ready state. (See Section 6, Commands.)

3) Error (ERROR) LED: Red

On:

Offline (except during paper feeding using the FEED button and during test printing,

 

and the error state). (refer to Section 2.1.1.2, Switching between online and offline)

Off:

Normal condition

Blinking: Error (refer to Section 3.7)

Figure 3.4.1 Panel Switches and Indicators

TITLE

TM-T88IIIseries

SHEET

NO.

REVISION

 

EPSON Specification (STANDARD)

B

NEXT

SHEET

56

55

 

 

 

 

Page 66
Image 66
Epson T88III specifications Panel LED Indicators, Standby State Indication