Confidential

GS W nL nH

[Name]

Set printing area width

 

 

[Format]

ASCII

GS

W

nL

nH

 

Hex

1D

57

nL

nH

 

Decimal

29

87

nL

nH

[Range]

0

nL

255

 

 

 

 

0

nH

255

 

 

 

[Description] Sets the printing area width to the area specified by nL and nH.

The printing area width is set to [(nL + nH 256) horizontal motion unit]]. Printable area

 

Left margin Printing area width

[Details]

This command is effective only processed at the beginning of the line.

 

In page mode, the printer performs only internal flag operations.

 

This command does not affect printing in page mode.

 

If the [left margin + printing area width] exceeds the printable area, [printable area width - left

 

margin) is used.

 

The horizontal and vertical motion units are specified by GS P. Changing the horizontal and

 

vertical motion units does not affect the current left margin.

 

The horizontal motion unit (x) is used for calculating the printing area width. The calculated

 

result is truncated to the minimum value of the mechanical pitch.

EPSON

TITLE

TM-T88IIIseries

SHEET

NO.

 

 

REVISION

 

 

 

Specification

 

 

 

 

 

NEXT

SHEET

 

(STANDARD)

B

 

 

 

 

129

128

Page 139
Image 139
Epson T88III specifications GS W nL nH