Installing a BlackDiamond 12800 Series Module
NOTE
Any unoccupied module slot in the chassis should have a blank faceplate installed to ensure satisfactory protection from EMI and to maintain adequate airflow through the chassis.
4Remove the module from the antistatic packaging as follows:
a Place the antistatic bag containing the module on a flat ESD surface that is clear of any debris. b Break the quality seal, the ESD warning seal, and the Read Installation Note seal.
c Open the antistatic bag and firmly grasp the rail of the module. d Pull the antistatic bag off while holding the rail of the module.
CAUTION
To prevent ESD damage, hold the module by the metal rail and front panel only. Never touch the components on the PCB or pins on any of the connectors.
5Verify that the module injector/ejector handles are open (Figure 63).
Figure 63: Injector/Ejector Handles in an Open Position
EX_123
6Keep the injector/ejector handles in the open position as you slide the module into the chassis slot.
CAUTION
Do not slide the module into the open chassis slot if the injector/ejector handles are in the latched position.
7Use both hands to latch the injector/ejector handles, by simultaneously pushing both handles toward the center of the module as shown in Figure 64.
BlackDiamond 12800 Series Switches Hardware Installation Guide | 103 |
|
|