Extreme Networks 325 W AC Power Supply
BlackDiamond 12800 Series Switches Hardware Installation Guide 99
Removing an Extreme Networks 325 W AC PSU
CAUTION
An operating 325 W AC PSU may be hot to the touch; use thermal protective gloves when handling the 325 W AC
PSU during removal.
CAUTION
To disconnect the system power, disconnect ALL power supply units. Disconnect the power cord before you remove
the PSU from the chassis.
To remove an Extreme Networks 325 W AC PSU:
1Attach an ESD-preventive wrist strap to your wrist and connect the metal end to the ground
receptacle on the top right corner of the switch front panel.
2Disconnect the AC power cord from the wall outlet.
3Loosen the middle screw on the power cord bracket to allow removal of the power cord. After the
screws are loosened, disconnect the AC power cord from the AC input on the front of the PSU.
4Loosen the two captive screws that secure the PSU front panel to the chassis frame.
5Use the handle to slide the PSU out of the chassis.
NOTE
Leave the ESD strap permanently connected to the switch, so that the strap is always available when you need to
handle ESD-sensitive components.
Front Panel LEDs
The front panel of the Extreme Networks 325 W AC PSU provides status LEDs. Tabl e 22 describes the
meanings of these LEDs.

Table 22: Extreme Networks 325 W AC PSU LEDs

PSU Condition
AC In
LED Status
DC Out
LED Status
No AC input power Off Off
No AC input power (receiving standby power from the chassis) Amber Off
AC input good (main outputs disabled) Green Off
AC input good, output fault Green Amber
AC input good, DC output good Green Green