Installing Power Supply Units

Removing the BlackDiamond 12804 AC Power Cord Retainer Channel

To remove the BlackDiamond 12804 AC power cord retainer channel:

1Attach the ESD-preventive wrist strap to your wrist and connect the metal end to the ground receptacle on the switch front panel.

2Using a #2 Phillips screwdriver, loosen the captive screw on each end of the power cord retainer channel.

3Remove the power cord retainer channel from the switch.

NOTE

Leave the ESD-preventive wrist strap permanently connected to the switch, so that the strap is always available when you need to handle ESD-sensitive components.

Extreme Networks 325 W DC Power Supply

This section describes how to install the Extreme Networks® 325 W DC UL-listed accessory power supply unit (PSU), Model # 65022, in a BlackDiamond 12802 switch

NOTE

For centralized DC power connection, this product is intended to be installed in restricted access locations (dedicated equipment rooms, equipment closets, or the like) in accordance with Articles 110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA 70.

NOTE

The Extreme Networks 325 W DC PSU cannot be used in combination with any other Extreme Networks PSU.

The 325 W DC PSU should be connected to a DC power source using the Extreme Networks DC power input cable Model # 65025. This cable is shipped separately from the power supply.

Minimum Software Required

You must be running ExtremeWare XOS version 12.0 or later for the system to recognize the DC PSU.

88

BlackDiamond 12800 Series Switches Hardware Installation Guide

 

 

Page 88
Image 88
Extreme Networks 12804, 12802 manual Extreme Networks 325 W DC Power Supply