Extreme Networks 325 W DC Power Supply
Figure 55: Connecting the DC Power Cord
Torino DC PSU_03A
NOTE
Leave the ESD strap permanently connected to the switch so that it is always available when you need to handle
Removing an Extreme Networks 325 W DC PSU
CAUTION
An operating 325 W DC PSU may be hot to the touch. Use thermal protective gloves when handling the 325 W DC PSU during removal.
CAUTION
To disconnect system power, disconnect ALL power supply units. Disconnect the power cord before you remove the PSU from the chassis.
To remove an Extreme Networks 325 W DC PSU:
1Turn off the DC power at the source.
2Attach an
3Press down the catch on the DC input connector and disconnect the DC power cord from the front of the PSU.
4Loosen the captive retaining screws on the PSU front panel.
5Use the handle to pull the PSU from the chassis.
NOTE
Disconnection of the DC power cord from the DC source voltage must be performed by a qualified, licensed electrician.
BlackDiamond 12800 Series Switches Hardware Installation Guide | 93 |
|
|