Technical Specifications

Table 24: BlackDiamond 12804 Switch Technical Specifications (Continued)

EMI/EMC Standards

 

North America EMC for ITE

FCC CFR 47 part 15 Class A (USA)

 

ICES-003 Class A (Canada)

European EMC standards

EN 55022:1998 Class A

 

EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11

 

EN 61000-3-2,3 (Harmonics & Flicker)

 

ETSI EN 300 386:2001 (EMC Telecommunications)

 

89/336/EEC EMC Directive

International EMC certifications

CISPR 22:1997 Class A (International Emissions)

 

CISPR 24:1997 Class A (International Immunity)

 

IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A

 

IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A

 

IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A

 

IEC/EN 61000-4-5 Surge, 2kV, 4kV, Criteria A

 

IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS,

 

Criteria A

 

IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C

Country-specific

VCCI Class A (Japan Emissions)

 

AS/NZS 3548 ACA (Australia Emissions)

 

CNS 13438:1997 Class A (BSMI-Taiwan)

 

MIC Mark, EMC Approval (North Korea)

Telecom Standards

IEEE 802.3 Media Access Standards

Note: These standards are module-specific and may not apply to every module in the series.

Environmental Standards

Environmental

ETSI EN 300 386:2001 (EMC Telecommunications)

ETSI EN 300 019 (Environmental for Telecommunications)

IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TX, 100BASE-FX

IEEE 802.3z 1000BASE-X

IEEE 802.3ab 1000BASE-T

IEEE 802.3ac VLAN Tag

IEEE 802.3ad Link Aggregation

IEEE 802.3ae 10GBASE-X

IEEE 802.3aef Power over Ethernet

EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise

Operating conditions

Operating temperature range: 0° C to 40° C (32° F to 104° F)

 

Operating humidity:10% to 93% relative humidity, non-condensing

 

Operating altitude 0 to 3000 meters (0 to 9,850 ft)

 

Operational shock: 30 m/s2 (3 g), 11 ms, 60 shocks

 

Operational random vibration: 5 to 500 Hz @ 1.5g rms