Extreme Networks 1200 W DC PSU
Removing an Extreme Networks 1200 W DC PSU
CAUTION
The DC PSU may be hot to the touch; use thermal protective gloves when handling the 1200 W DC PSU during removal.
To remove an Extreme Networks 1200 W DC PSU:
1Attach an
2
3Press the yellow lever on the DC PSU to the left while lifting the handle up on the 1200 W DC PSU.
4Disconnect the cable from the front of the DC PSU by pressing down the catch (see Figure 44) and pulling out the cable.
Figure 44: Disconnecting the Cable from the DC PSU
Squeeze catch to release plug
EX_133
WARNING!
Always be sure that the 1200 W DC PSU does not have the input cabled connected at any time when the DC PSU is not installed into the switch. Do not remove the DC PSU from the switch before disconnecting the input DC cable from the PSU.
5Pull on the handle of the 1200 W DC PSU to slide it out of the power supply bay.
6Wearing thermal protection gloves, place both hands underneath the 1200 W DC PSU to support the weight after it is pulled out from the switch.
To remove additional 1200 W DC PSUs, repeat steps 2 through 6.
NOTE
Leave the ESD strap permanently connected to the switch, so that the strap is always available when you need to handle
BlackDiamond 12800 Series Switches Hardware Installation Guide | 79 |
|
|