System problems

The system will not start up

Probable cause

Solution

 

 

The system is not connected to

Make sure that the power cable is connected to an

an AC outlet

operating AC power source.

 

 

Voltage selection switch not

Make sure that the voltage selection switch is set to

set correctly

the correct power source.

 

 

A power supply module has

Power supply alarm buzzes and power supply status

failed

LED blinks indicating a failed power supply module.

 

Replace the indicated power supply module. (You can

 

turn off the audible alarm by inserting an appropriate

 

tool into the port on the front panel and pressing the

 

switch.)

 

 

The power supply has failed

The power supply alarm buzzes and all power supply

 

status LEDs blink, indicating a failed common

 

component.

 

Replace the entire power supply housing. (One or

 

more of the power supply modules may also be bad.)

 

 

The system is non-responsive

Probable cause

Solution

 

 

An error occurs during an

Restart your server by pressing the reset button. If the

application or the server

system is still non-responsive, press and hold in the power

may be out of memory

button for 4 seconds to turn the server off. Turn the server

 

back on, then follow the on-screen instructions.

 

 

Keyboard, mouse, and front

Enter the password.

panel are locked out when

 

the password is set

 

 

 

The keyboard does not work

Probable cause

Solution

 

 

Keyboard is locked out

Enter the password.

when the password is set

 

 

 

138Troubleshooting