Additional beep codes provided by optional Intel Management Modules

In addition to the preceding beep codes, the following additional beep codes are provided if an Intel Management Module is installed:

Beep Codes

Description

 

 

1

Control panel CMOS clear has been initiated

 

 

1-5-1-1

Processor failure. Reseat or replace the failed processor.

 

 

1-5-2-1

No processor is installed or the CPU 1 socket is empty.

 

Reseat or replace the failed processor.

 

 

1-5-2-3

Processor configuration error or CPU 1 socket is empty.

 

Reseat or replace the failed processor. In a

 

two-processor system, make sure the processors are

 

identical.

 

 

1-5-2-4

Front-side bus select configuration error.

 

 

1-5-4-2

DC power unexpectedly lost.

 

 

1-5-4-3

Chipset control failure.

 

 

1-5-4-4

Power control failure.

 

 

LED information

The system board in this server includes LEDs that can assist you in troubleshooting your system. See the following table for a description of these LEDs and the information they provide:

LED NameFunctionLocationColor

Description

 

 

 

 

 

ID

Aid in server

Front panel and

Blue

On = Server identification

 

identification

left back of

 

enabled

 

 

system board

 

 

 

 

 

 

 

System Fault

Visible fault

Front panel and

Green or

On = No fault

 

warning

left back of

Orange

Green blink = Degraded

 

 

system board

 

Orange = Critical error or

 

 

 

 

non-recoverable

 

 

 

 

Orange blink = Non critical

 

 

 

 

 

ATA drive

Indicate drive

Front panel and

Green

Blinking = Drive active

activity

activity

left side of

 

 

 

 

system board

 

 

 

 

 

 

 

126