In addition to the preceding beep codes, the following additional beep codes are provided if an Intel Management Module is installed:
Beep Codes | Description |
|
|
1 | Control panel CMOS clear has been initiated |
|
|
Processor failure. Reseat or replace the failed processor. | |
|
|
No processor is installed or the CPU 1 socket is empty. | |
| Reseat or replace the failed processor. |
|
|
Processor configuration error or CPU 1 socket is empty. | |
| Reseat or replace the failed processor. In a |
| |
| identical. |
|
|
|
|
DC power unexpectedly lost. | |
|
|
Chipset control failure. | |
|
|
Power control failure. | |
|
|
The system board in this server includes LEDs that can assist you in troubleshooting your system. See the following table for a description of these LEDs and the information they provide:
LED Name | Function | Location | Color | Description |
|
|
|
|
|
ID | Aid in server | Front panel and | Blue | On = Server identification |
| identification | left back of |
| enabled |
|
| system board |
|
|
|
|
|
|
|
System Fault | Visible fault | Front panel and | Green or | ■ On = No fault |
| warning | left back of | Orange | ■ Green blink = Degraded |
|
| system board |
| ■ Orange = Critical error or |
|
|
|
| |
|
|
|
| ■ Orange blink = Non critical |
|
|
|
|
|
ATA drive | Indicate drive | Front panel and | Green | Blinking = Drive active |
activity | activity | left side of |
|
|
|
| system board |
|
|
|
|
|
|
|
126 | www.gateway.com |