Environmental specifications

The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.

VariableRequirements

Temperature

Nonoperating: -40° to 158°F (-40° to 70°C)

 

Operating: 50° to 95°F (10° to 35°C) with a maximum rate of change

 

not to exceed 10° per hour

Humidity

Nonoperating: 90% relative (noncondensing) at 95° F (35° C)

Acoustic noise

Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office

 

ambient temperature. (73.4 +/- ° F) Sound Power: 7.0 BA in an idle

 

state at typical office ambient temperature. (73.4 +/- 3.6° F)

Shock

Operating - 2.0 g, 11 mSec, 1/2 sine

 

Unpackaged - Trapezoidal, 25 g, velocity change 136 inches/sec

 

( 40 lbs to > 80 lbs).

 

Packaged - Non-palletized free fall in height 24 inches ( 40 lbs to

 

> 80 lbs)

Vibration

5 Hz to 500 Hz, 2.20 g RMS random

Electrostatic

Tested to +/-15 kV, except I/O port +/- 8kV per Intel Environmental

discharge (ESD)

test specification

System cooling

2322 BTU/hour (Based on 520W maximum power, 78% power

requirement in

subsystem efficiency, and 98% power factory correction loss)

BTU/Hr

 

144